Visual and region of interest-based inter-rater agreement in the assessment of the diffusion-weighted imaging- fluid-attenuated inversion recovery mismatch.

نویسندگان

  • Ivana Galinovic
  • Josep Puig
  • Lars Neeb
  • Jorge Guibernau
  • Andre Kemmling
  • Susanne Siemonsen
  • Salvador Pedraza
  • Bastian Cheng
  • Götz Thomalla
  • Jens Fiehler
  • Jochen B Fiebach
چکیده

BACKGROUND AND PURPOSE WAKE-UP is a randomized, placebo-controlled MRI-based trial of thrombolysis in wake-up stroke using the mismatch between a lesion's visibility in diffusion-weighted imaging and fluid-attenuated inversion recovery (FLAIR) sequences as its main imaging inclusion criterion. Visual judgment of lesion conspicuity on FLAIR is however methodically limited by moderate inter-rater agreement. We therefore sought to improve rating homogeneity by incorporating quantitative signal intensity measurements. METHODS One hundred forty-three data sets of patients with acute ischemic stroke were visually rated by 8 raters with respect to WAKE-UP study inclusion and exclusion criteria, and inter-rater agreement was calculated. A subanalysis was performed on 45 cases to determine a threshold value of relative signal intensity (rSI) between the ischemic lesion and contralateral healthy tissue which best corresponded to a visually established verdict of FLAIR positivity. The usefulness of this threshold in improving inter-rater agreement was evaluated in an additional sample of 50 patients. RESULTS Inter-rater agreement for inclusion into the WAKE-UP trial was 73% with a free-marginal κ of 0.46. A threshold of rSI which best correlated with the visual rating of lesions as FLAIR positive was 1.20. The addition of rSI measurements to visual evaluation did not change the inter-rater agreement. CONCLUSIONS Introducing a semiquantitative measure for FLAIR rSI did not improve the agreement between individual raters. However, enhancing visual assessment with rSI measurements can provide reassurance to local investigators in cases of uncertainty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Color-coded fluid-attenuated inversion recovery images improve inter-rater reliability of fluid-attenuated inversion recovery signal changes within acute diffusion-weighted image lesions.

BACKGROUND AND PURPOSE Diffusion-weighted image fluid-attenuated inversion recovery (FLAIR) mismatch has been considered to represent ischemic lesion age. However, the inter-rater agreement of diffusion-weighted image FLAIR mismatch is low. We hypothesized that color-coded images would increase its inter-rater agreement. METHODS Patients with ischemic stroke <24 hours of a clear onset were re...

متن کامل

Prediction of Stroke Onset Is Improved by Relative Fluid-Attenuated Inversion Recovery and Perfusion Imaging Compared to the Visual Diffusion-Weighted Imaging/Fluid-Attenuated Inversion Recovery Mismatch.

BACKGROUND AND PURPOSE Acute stroke patients with unknown time of symptom onset are ineligible for thrombolysis. The diffusion-weighted imaging and fluid-attenuated inversion recovery (FLAIR) mismatch is a reasonable predictor of stroke within 4.5 hours of symptom onset, and its clinical usefulness in selecting patients for thrombolysis is currently being investigated. The accuracy of the visua...

متن کامل

Test-Retest and Inter-Rater Reliability Study of the Schedule for Oral-Motor Assessment in Persian Children

Objectives: Reliable and valid clinical tools to screen, diagnose, and describe eating functions and dysphagia in children are highly warranted. Today most specialists are aware of the role of assessment scales in the treatment of affected individuals. However, the problem is that the clinical tools used might be nonstandard, and worldwide, there is no integrated assessment performed to assess ...

متن کامل

Does b1000-b0 Mismatch Challenge Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery Mismatch in Stroke?

BACKGROUND AND PURPOSE Our aim was to explore whether the mismatch in lesion visibility between b1000 and b0 images is an alternative to mismatch between diffusion-weighted imaging and fluid-attenuated inversion recovery imaging as a surrogate marker of stroke age. METHODS We analyzed patients from the European multicenter I-KNOW database. Independent readers assessed the visibility of ischem...

متن کامل

Reliability of measuring lesion volumes in transient ischemic attack and minor stroke.

BACKGROUND AND PURPOSE Lesion volume measurements in disabling ischemic stroke have excellent reliability, but it is not clear whether this is also true for small lesions. We assessed the reliability of measuring baseline and follow-up lesion volumes in transient ischemic attack and minor stroke. METHODS Patients who presented with a transient ischemic attack or minor stroke (NIHSS < or = 3) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 45 4  شماره 

صفحات  -

تاریخ انتشار 2014