Prasugrel plus aspirin beyond 12 months is associated with improved outcomes after TAXUS Liberté paclitaxel-eluting coronary stent placement.

نویسندگان

  • Kirk N Garratt
  • W Douglas Weaver
  • Ronald G Jenkins
  • Thomas K Pow
  • Laura Mauri
  • Dean J Kereiakes
  • Kenneth J Winters
  • Thomas Christen
  • Dominic J Allocco
  • David P Lee
چکیده

BACKGROUND The TAXUS Liberté Post Approval Study (TL-PAS) contributed patients treated with TAXUS Liberté paclitaxel-eluting stent and prasugrel to the Dual Antiplatelet Therapy Study (DAPT) that compared 12 and 30 months thienopyridine plus aspirin therapy after drug-eluting stents. METHODS AND RESULTS Outcomes for 2191 TL-PAS patients enrolled into DAPT were assessed. The DAPT coprimary composite end point (death, myocardial infarction [MI], or stroke) was lower with 30 compared with 12 months prasugrel treatment (3.7% versus 8.8%; hazard ratio [HR], 0.407; P<0.001). Rates of death and stroke were similar between groups, but MI was significantly reduced with prolonged prasugrel treatment (1.9% versus 7.1%; HR, 0.255; P<0.001). The DAPT coprimary end point, stent thrombosis, was also lower with longer therapy (0.2% versus 2.9%; HR, 0.063; P<0.001). MI related to stent thrombosis (0% versus 2.6%; P<0.001) and occurring spontaneously (1.9% versus 4.5%; HR, 0.407; P=0.007) were both reduced with prolonged prasugrel. MI rates increased within 90 days of prasugrel cessation after both 12 and 30 months treatment. Composite Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Coronary Arteries (GUSTO) moderate or severe bleeds were modestly increased (2.4% versus 1.7%; HR, 1.438; P=0.234) but severe bleeds were not more frequent (0.3% versus 0.5%; HR, 0.549; P=0.471) in the prolonged treatment group. CONCLUSIONS Prasugrel and aspirin continued for 30 months reduced ischemic events for the TAXUS Liberté paclitaxel-eluting stent patient subset from DAPT through reductions in MI and stent thrombosis. Withdrawal of prasugrel was followed by an increase in MI after both 12 and 30 months therapy. The optimal duration of dual antiplatelet therapy with prasugrel after TAXUS Liberté paclitaxel-eluting stent remains unknown, but appears to be >30 months. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT00997503.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rationale and design of the TAXUS Libertē Post-Approval Study: examination of patients receiving the TAXUS Liberté stent with concomitant prasugrel therapy in routine interventional cardiology practice.

BACKGROUND Observational studies of new coronary stents are necessary to assess performance in a variety of complex patient and lesion types. Furthermore, the optimal dose and duration of thienopyridine treatment is unclear, particularly in patients with complex clinical conditions. The TAXUS Libertē Post-Approval Study is designed to provide 5-year data on the TAXUS Liberté paclitaxel-eluting ...

متن کامل

New stent design for use in small coronary arteries during percutaneous coronary intervention

Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS(®) Liberté(®) Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel), and release kinetics as the first-gene...

متن کامل

Six-month results of the NEVO Res-Elution I (NEVO RES-I) trial: a randomized, multicenter comparison of the NEVO sirolimus-eluting coronary stent with the TAXUS Liberté paclitaxel-eluting stent in de novo native coronary artery lesions.

BACKGROUND Drug-eluting stents reduce restenosis and reintervention rates but are complicated by stent thrombosis, which may be related to polymer coating. The NEVO sirolimus-eluting coronary stent (NEVO SES) is designed to improve long-term percutaneous coronary intervention safety by combining sirolimus release from reservoirs with bioabsorbable polymer to reduce spatial and temporal polymer ...

متن کامل

Reduced risk of restenosis in small vessels and reduced risk of myocardial infarction in long lesions with the new thin-strut TAXUS Liberté stent: 1-year results from the TAXUS ATLAS program.

OBJECTIVES The TAXUS ATLAS Small Vessel (SV) and Long Lesion (LL) multicenter studies compared the performance of the thin-strut (0.0038 inch) TAXUS Liberté 2.25-mm stent (Boston Scientific; Natick, Massachusetts) and the TAXUS Liberté 38-mm long stent (Boston Scientific; Natick, Massachusetts) with the earlier paclitaxel-eluting TAXUS Express (Boston Scientific) stent that has identical polyme...

متن کامل

A novel paclitaxel-eluting stent with an ultrathin abluminal biodegradable polymer 9-month outcomes with the JACTAX HD stent.

OBJECTIVES The JACTAX HD trial ("JACTAX" Trial Drug Eluting Stent Trial) evaluated the safety and clinical performance of a novel JACTAX HD (Boston Scientific Corporation, Natick, Massachusetts) paclitaxel-eluting stent (PES) in de novo coronary lesions. BACKGROUND The JACTAX HD (Boston Scientific) stent consists of a pre-crimped bare-metal Liberté (Boston Scientific) stent coated on its ablu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 132 13  شماره 

صفحات  -

تاریخ انتشار 2015