Assessment of thrombocytopenic disorders using the Platelet Function Analyzer (PFA-100).
نویسندگان
چکیده
The Platelet Function Analyzer (PFA-100) was used to measure platelet function in paediatric patients with destructive versus underproduction thrombocytopenia. Closure time (CT) and total volume (TV) measurements with standard 150 microm apertures discriminated between patients with similar platelet counts from 30 to 150 x 10(9)/l. However, at platelet counts < 30 x 10(9)/l, a 100-microm aperture (experimental) gave the best assessment of platelet function. TV results could be analysed even when CTs were indeterminate. Further investigations are warranted to more fully understand the relationships among platelet function as measured by the PFA-100 in standard/experimental modes, bleeding and transfusion outcome in thrombocytopenia.
منابع مشابه
Platelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function: a rebuttal.
BACKGROUND Closure time (CT), measured by platelet function analyzer (PFA-100) device, is now available to the clinical laboratory as a possible alternative or supplement to the bleeding time test. AIM On behalf of the Platelet Physiology Subcommittee of the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis (ISTH-SSC), a working Group was form...
متن کاملAnti-D immunoglobulin in children with newly diagnosed immune thrombocytopenic purpura: a pilot study.
1. Angelini A, Dragani A, Berardi A, Iacone A, Fioritoni G, Tortolano G. Evaluation of four different methods for platelet freezing. In vitro and in vivo studies. Vox Sang 1992; 62:146-51. 2. Currie LM, Livesey SA, Harper JR, Connor J. Cryopreservation of single-donor platelets with a reduced dimethyl sulfoxide concentration by addition of second-messenger effectors: enhanced retention of in vi...
متن کاملEffects of Increased Von Willebrand Factor Levels on Primary Hemostasis in Thrombocytopenic Patients with Liver Cirrhosis
In patients with liver cirrhosis procoagulant and anticoagulant changes occur simultaneously. During primary hemostasis, platelets adhere to subendothelial structures, via von Willebrand factor (vWF). We aimed to investigate the influence of vWF on primary hemostasis in patients with liver cirrhosis. Therefore we assessed in-vitro bleeding time as marker of primary hemostasis in cirrhotic patie...
متن کاملEvaluation of acquired platelet dysfunctions in uremic and cirrhotic patients using the platelet function analyzer (PFA-100 ): influence of hematocrit elevation.
BACKGROUND AND OBJECTIVE Patients with end-stage renal disease or advanced cirrhosis develop bleeding disorders characterized by defective interaction of platelets with damaged subendothelium. The anemia associated with both clinical entities has a negative influence on hemostasis. We evaluated alterations of platelet function in patients suffering from end-stage renal disease (n=21) or hepatic...
متن کاملPFA-100 test in the detection of platelet dysfunction and monitoring DDAVP in a patient with liver cirrhosis undergoing inguinal hernia repair.
INTRODUCTION Hemostatic abnormalities in liver cirrhosis are complex and multifactorial and may predispose to prolonged hemorrhage following invasive procedures. Due to increased perioperative bleeding risks, patients with cirrhosis should undergo elective surgery after making medical preparations. It has been shown that 1-deamino-8-D-arginine vasopressin (DDAVP), desmopressin, can be used as a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of haematology
دوره 117 4 شماره
صفحات -
تاریخ انتشار 2002