Some Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid Xe Clearance Curve A QUANTITATIVE EVALUATION EMPLOYING A DIGITAL MODEL
نویسنده
چکیده
Some Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid Xe Clearance Curve • A digital model study has been developed for quantitative assessment of experimental errors in the analysis of Xe clearance curve from the brain. A small Computer synthesized a model of the clearance curve, varying combinations of fast and slow components. The curves were convoluted with Poisson random digits to simulate statistical fluctuations. Identical curves were overlapped with varying intervals to study the influence of remaining activity. The height over area method to ten minutes was confirmed to overestimate CBF by 10% to 15% with a slow component of 20 ml/100 gm per minute, and the overestimation was increased with a lower slow flow component. The initial slope value was shown to have a close relationship with the fast flow component when the latter was less than 100 ml/100 gm per minute. Errors due to statistical fluctuations were determined only by the initial height (Ho cps), as the percent standard deviation was AH0/H0_m the height over area method and 2AH0/H0logH0 in the initial slope method, where AH0 = VH0. Remaining activity caused errors of 1% to 3% in the initial slope method with an injection interval of 15 minutes. The influence of remaining activity can be eliminated with an injection interval of more than 25 to 30 minutes in the initial slope method and more than 40 minutes in the height over area method. Additional
منابع مشابه
Some Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid
Some Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid Xe Clearance Curve • A digital model study has been developed for quantitative assessment of experimental errors in the analysis of Xe clearance curve from the brain. A small Computer synthesized a model of the clearance curve, varying combinations of fast and slow components. The curves were convoluted w...
متن کاملSome experimental errors in calculating regional cerebral blood flow from the intracarotid 133Xe clearance curve. A quantitative evaluation employing a digital model.
A digital model study has been developed for quantitative assessment of experimental errors in the analysis of 133Xe clearance curve from the brain. A small computer synthesized a model of the clearance curve, varying combinations of fast and slow components. The curves were convoluted with Poisson random digits to simulate statistical fluctuations. Identical curves were overlapped with varying...
متن کاملRegional Cerebral Blood Flow Measured by the Gamma Camera After Direct Injection of Xe into the Distal Stump of the Occluded Middle Cerebral Artery
Regional Cerebral Blood Flow Measured by the Gamma Camera After Direct Injection of Xe into the Distal Stump of the Occluded Middle Cerebral Artery • Regional cerebral blood flow (rCBF) was measured after intracarotid injection of Xe concurrently with measurements of local cerebral blood flow (LCBF) after injection of Xe directly into the distal stump of the occluded middle cerebral artery (MCA...
متن کاملSpectrum Subtraction Technique for Minimizing Extracranial Influence on Cerebral Blood Flow Measurements by Xenon Inhalation
Estimates of regional cerebral blood flow (rCBF) by the Xe inhalation method are influenced by isotope contamination from slow clearing extracerebral tissues. Subtraction of x-ray (31 kev) from gamma-ray counts (81 kev) has been suggested as a means of yielding clearance curves that are relatively free of such contamination. In the present study, rCBF measurements based on the total Xe spectrum...
متن کاملClearance for Determining Regional Cerebral Blood Flow in a Primate Model
A technique for stochastic analysis of '"Xe washout using a computer-assisted Anger camera is described. The technique produces functional maps of both regional cerebral blood flow (rCBF) and error in rCBF. The calculations! limitations of the technique are discussed and an experimental estimate made of the physical limitations associated with the low energy photon emitted by "Xe. The method is...
متن کامل