A randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction.

نویسندگان

  • Melchior Seyfarth
  • Dirk Sibbing
  • Iris Bauer
  • Georg Fröhlich
  • Lorenz Bott-Flügel
  • Robert Byrne
  • Josef Dirschinger
  • Adnan Kastrati
  • Albert Schömig
چکیده

OBJECTIVES The aim of this study was to test whether the left ventricular assist device (LVAD) Impella LP2.5 (Abiomed Europe GmbH, Aachen, Germany) provides superior hemodynamic support compared with the intra-aortic balloon pump (IABP). BACKGROUND Cardiogenic shock caused by left ventricular failure is associated with high mortality in patients with acute myocardial infarction (AMI). An LVAD may help to bridge patients to recovery from left ventricular failure. METHODS In a prospective, randomized study, 26 patients with cardiogenic shock were studied. The primary end point was the change of the cardiac index (CI) from baseline to 30 min after implantation. Secondary end points included lactic acidosis, hemolysis, and mortality after 30 days. RESULTS In 25 patients the allocated device (n = 13 IABP, n = 12 Impella LP2.5) could be safely placed. One patient died before implantation. The CI after 30 min of support was significantly increased in patients with the Impella LP2.5 compared with patients with IABP (Impella: DeltaCI = 0.49 +/- 0.46 l/min/m(2); IABP: DeltaCI = 0.11 +/- 0.31 l/min/m(2); p = 0.02). Overall 30-day mortality was 46% in both groups. CONCLUSIONS In patients presenting with cardiogenic shock caused by AMI, the use of a percutaneously placed LVAD (Impella LP 2.5) is feasible and safe, and provides superior hemodynamic support compared with standard treatment using an intra-aortic balloon pump. (Efficacy Study of LV Assist Device to Treat Patients With Cardiogenic Shock [ISAR-SHOCK]; NCT00417378).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock.

BACKGROUND AND AIM Despite major advances in the treatment of heart failure, cardiogenic shock (CGS) remains associated with substantial mortality. Recent data suggest that the TandemHeart percutaneous ventricular assist device (pVAD) may be useful in the management of CGS. The aim of this prospective randomized study was to test the hypothesis that the TandemHeart (pVAD) provides superior hemo...

متن کامل

Percutaneous left ventricular assist devices in acute myocardial infarction complicated by cardiogenic shock.

Cardiogenic shock (CS) remains the most common cause of death in patients with acute myocardial infarction (AMI). In addition to percutaneous coronary intervention, inotropes, and fluids, intraaortic balloon pumping (IABP) is most widely used for initial haemodynamic stabilization. However, the main limitation of IABP is the lack of active circulatory support and the requirement of a certain le...

متن کامل

Mechanical circulatory support in acute cardiogenic shock

Cardiogenic shock complicates about 5% to 8% of all admissions for acute myocardial infarction, and despite advancement in treatment over the past 50 years, mortality remains unacceptably high. Management with vasoactive agents after revascularization can have its limitations and thus mechanical circulatory support is often initiated. Intra-aortic balloon pumps (IABPs) are the devices most comm...

متن کامل

The spectrum of haemodynamic support in cardiogenic shock: how to choose and use.

Copyright © Polskie Towarzystwo Kardiologiczne INTRODUCTION Cardiogenic shock is still the most important prognostic factor for short-term mortality in acute coronary syndromes, with mortality rates approaching 50% at 30 days [1, 2]. Haemodynamic support can be achieved by inotropics and/or vasopressors as well as mechanical means such as intra-aortic balloon pumping (IABP) or percutaneous impl...

متن کامل

Intra-aortic balloon pump: indications, efficacy, guidelines and future directions.

PURPOSE OF REVIEW The intra-aortic balloon pump (IABP) has been used as a cardiac assist device in various clinical situations since 1968 on the basis of the physiological principles and observational data, with little randomized data until recently. RECENT FINDINGS Recently published randomized controlled trials (RCTs) and meta-analyses have demonstrated acceptable safety for IABP but have r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 52 19  شماره 

صفحات  -

تاریخ انتشار 2008