Repeated exposure to benzalkonium chloride in the Ex Vivo Eye Irritation Test (EVEIT): observation of isolated corneal damage and healing.

نویسندگان

  • Markus Frentz
  • Miriam Goss
  • Martin Reim
  • Norbert F Schrage
چکیده

The prediction of side-effects is a key issue in the REACH initiative on chemicals, in the production of cosmetics and in the preclinical testing of drugs. A new ex vivo test for repeated substance application is presented, that is able to identify corrosive and irritant effects on the eye by using crucial endpoints, such as cellular and morphological damage, and healing characteristics. The test is intended to replace the Draize eye test and to improve the preclinical testing of drugs and chemicals that are likely to come into direct contact with the cornea. The Ex Vivo Eye Irritation Test (EVEIT) is a self-healing system, involving living corneas obtained from abattoir rabbit eyes. The corneas are cultured in a similar way to the method used during the transplantation of corneal grafts. The corneas are exposed to multiple small, mechanical abrasions, and then test substances are repeatedly dropped onto the centres of the corneas. The test substances applied in this study were citrate-buffered hyaluronate eye drops and an artificial tear replacement, with increasing concentrations of up to 0.1% benzalkonium chloride. A dose-dependent inhibition of recovery and impairment of the lactate production mechanism in the cornea was observed with benzalkonium chloride treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changing the composition of buffered eye-drops prevents undesired side effects.

PURPOSE The Ex Vivo Eye Irritation Test (EVEIT) is used to analyse the clinical observations of corneal calcification attributed to the presence of phosphate within applied eye-drops used in treating glaucoma, Still-Chauffard syndrome, ocular burns and dry eyes. METHOD Live corneas from abattoir rabbit eyes were cultured in order to study epithelial healing following mechanical abrasion of th...

متن کامل

Corneal epithelial toxicity of antiglaucoma formulations: in vitro study of repeated applications

BACKGROUND By using a biologically relevant and sensitive three-dimensional model of human corneal epithelium and multiple endpoint analysis, assessment of the potential for eye irritation and long-term compatibility of four registered ophthalmological preparations, ie, Timolabak(®), Timoptol(®), Nyogel(®), and Timogel(®), was performed. This approach enables classification of the potential for...

متن کامل

Ocular safety of cationic emulsion of cyclosporine in an in vitro corneal wound-healing model and an acute in vivo rabbit model

PURPOSE Topical preparations of cyclosporine (CsA) are common therapeutics for the treatment of dry eye. However, they are not devoid of side effects, such as allergy and irritation. The present study aimed at evaluating the safety profile of a new CsA formulation in cationic emulsion (CEm) in vitro with a dynamic corneal wound healing assay using human corneal epithelial (HCE) cells, and in vi...

متن کامل

Localization and Expression of Zonula Occludins-1 in the Rabbit Corneal Epithelium following Exposure to Benzalkonium Chloride

Preservatives are a major component of the ophthalmic preparations in multi-dose bottles. The purpose of this study was to investigate the acute effect of benzalkonium chloride (BAC), a common preservative used in ophthalmic preparations, on the localization and expression of zonula occludens (ZO)-1 in the rabbit corneal epithelium in vivo. BAC at 0.005%, 0.01%, or 0.02% was topically applied t...

متن کامل

New tools for the evaluation of toxic ocular surface changes in the rat.

PURPOSE To assess the usefulness of noninvasive combined technologies used to observe ocular surface changes in toxicology studies. METHODS Benzalkonium chloride (BAC) at 0.01%, 0.1%, 0.25%, and 0.5% was applied to rat corneas for 11 days. The eye was evaluated macroscopically from day (D)0 to D52. The cornea was examined with the slit lamp, a fluorescein test was performed, and a confocal mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Alternatives to laboratory animals : ATLA

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2008