Magnetic resonance imaging based correction and reconstruction of positron emission tomography images

نویسنده

  • Jonathan Oakley
چکیده

Due to the inherently limited resolution of Positron Emission Tomography (PET) scanners, quantitative measurements taken from PET images suffer from the partial volume averaging of activity across regions of interest. A correction for this effect in PET activity distributions is therefore essential to distinguish differences due to changes in tracer concentration from those due to changes in the volumes of the active brain tissue. Various consequent image post-processing techniques have been developed to address this problem (see, for example, [1– 6]). These operate using associated high resolution anatomical images such as Magnetic Resonance Imaging (MRI), but as well as being highly susceptible to errors in the requisite registration and segmentation procedures, the methods are reliant on unrealistic simplifying assumptions regarding activity distributions in the brain. This work instead couples the correction of PET data to the reconstruction process itself, presenting a two-step scheme using associated MRI data to achieve this. The first step estimates the prior activity distributions from a segmented and intensity transformed MRI image. This is then used in the second step to constrain the Bayesian PET reconstruction with varying degrees of stringency. The prior, or initial correction process, is applied in the form of an energy term, adapted in accordance to an entropy measure taken on the MRI segmentation; i.e., where there is anatomical variation, we assume there also to be activity variation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

MR-Based PET Motion Correction Procedure for Simultaneous MR-PET Neuroimaging of Human Brain

Positron Emission Tomography (PET) images are prone to motion artefacts due to the long acquisition time of PET measurements. Recently, simultaneous magnetic resonance imaging (MRI) and PET have become available in the first generation of Hybrid MR-PET scanners. In this work, the elimination of artefacts due to head motion in PET neuroimages is achieved by a new approach utilising MR-based moti...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

Quantitative simultaneous positron emission tomography and magnetic resonance imaging.

Simultaneous positron emission tomography and magnetic resonance imaging (PET-MR) is an innovative and promising imaging modality that is generating substantial interest in the medical imaging community, while offering many challenges and opportunities. In this study, we investigated whether MR surface coils need to be accounted for in PET attenuation correction. Furthermore, we integrated moti...

متن کامل

Amplitude-based data selection for optimal retrospective reconstruction in micro-SPECT.

Respiratory motion can blur the tomographic reconstruction of positron emission tomography or single-photon emission computed tomography (SPECT) images, which subsequently impair quantitative measurements, e.g. in the upper abdomen area. Respiratory signal phase-based gated reconstruction addresses this problem, but deteriorates the signal-to-noise ratio (SNR) and other intensity-based quality ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999