Comparison of 2-year angiographic outcomes of stent- and nonstent-assisted coil embolization in unruptured aneurysms with an unfavorable configuration for coiling.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Stents are known to have hemodynamic and biologic effects in addition to their mechanical scaffold effect. To determine whether stents affect long-term outcomes after coiling of unruptured aneurysms, we compared angiographic outcomes at 2 years postembolization for stent- and nonstent-assisted coiled unruptured aneurysms. MATERIALS AND METHODS Stent-assisted coiling was used in unruptured aneurysms unfavorable for simple coiling (neck size >4 mm and dome-to-neck ratio <1.5) in our practice. Therefore, 126 coiled unruptured aneurysms in total (40 [31.7%] stent group and 86 [68.3%] nonstent group) with these conditions were selected for this study. The nonstent group aneurysms were treated with multiple microcatheter technique (53 cases) or balloon-assisted technique (33 cases). Self-expandable stents were used for coiling in stent group aneurysms. No significant difference in aneurysmal characteristics (aneurysm type [sidewall/bifurcation], diameter, neck size, and dome-to-neck ratio) or angiographic outcome at embolization (packing attenuation, obliteration grade, and contrast filling) were observed between the 2 study groups. RESULTS At 2-year follow-up visits, rates of progressive occlusion (stent group, 17/40 [42.5%] versus nonstent group, 34/86 [39.5%]) and recanalization (7/40 [17.5%] versus 18/86 [21.0%]) did not show a statistically significant difference between the 2 groups (P = .895). CONCLUSIONS The present study did not show that additional hemodynamic and biologic effects of stents designed for neck remodeling were enough to enhance progressive occlusion and prevent the recanalization of unruptured aneurysms. Our finding suggests that stent placement provides no better long-term angiographic outcomes for unruptured aneurysms with an unfavorable configuration for coiling.
منابع مشابه
Thromboembolic Event Detected by Diffusion Weighted Magnetic Resonance Imaging After Coil Embolization of Cerebral Aneurysms
OBJECTIVE The purpose of this study was to evaluate the occurrence rate of diffusion positive lesions (DPLs), and to assess the peri-procedural risk factors for the occurrence of DPLs in patients who underwent coil embolization of cerebral aneurysms. MATERIALS AND METHODS A total of 304 saccular aneurysms were embolized during a seven-year period from Jan 2007 to Dec 2013. Of these, postopera...
متن کاملExtending the indications of flow diversion to small, unruptured, saccular aneurysms of the anterior circulation.
BACKGROUND AND PURPOSE Flow diverters are currently indicated for treatment of large and complex intracranial aneurysms. The purpose of this study was to determine whether the indications of flow diversion can be safely extended to unruptured, small, saccular aneurysms (<10 mm) of the anterior circulation. METHODS Forty patients treated with the pipeline embolization device (PED) were matched...
متن کاملCoil Embolization of Wide-Neck Bifurcation Aneurysms Using a Single-Balloon Microcatheter.
BACKGROUND Coil embolization of wide-neck cerebral aneurysms frequently requires stent or balloon assistance. Such approaches to coil embolization increase the procedural complexity, adding risk and cost. OBJECTIVE To describe a series of coil embolization procedures performed using a single-balloon microcatheter to treat wide-neck aneurysms and establish the safety, feasibility and efficacy ...
متن کاملEndovascular Treatment of Intracranial Vertebral Artery Dissecting Aneurysms: Follow up Angiographic and Clinical Results of Endovascular Treatment in Serial Cases
PURPOSE To report angiographic and clinical results of endovascular treatment in 45 intracranial vertebral artery dissecting aneurysms (VADAs). MATERIALS AND METHODS From July 2002 to September 2013, a total of 42 patients with 45 VADAs received endovascular treatment. Endovascular treatment consisted of internal trapping with detachable coils, stent-assisted coiling, and stenting only. Immed...
متن کاملAngiographic Results of Wide-Necked Intracranial Aneurysms Treated with Coil Embolization : A Single Center Experience
OBJECTIVE Endovascular treatment of wide-necked intracranial aneurysms is a challenge and the durability and the safety of these treated aneurysms remain unknown. The aim of this study was to evaluate the clinical and long-term angiographic results of wide-necked intracranial aneurysms treated with coil embolization. METHODS Between January 2002 and December 2012, 53 wide-necked aneurysms tre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 32 9 شماره
صفحات -
تاریخ انتشار 2011