Edge–Preserving Metal Artifact Reduction in Computed Tomography

نویسندگان

  • Esther Meyer
  • Rainer Raupach
  • Michael Lell
  • Bernhard Schmidt
  • Marc Kachelrieß
چکیده

Esther Meyer1,2, Rainer Raupach2, Michael Lell3, Bernhard Schmidt2, and Marc Kachelrieß1,4 1Institute of Medical Physics, Friedrich–Alexander University of Erlangen–Nürnberg (FAU), Erlangen, Germany  2Siemens Healthcare, Forchheim, Germany 3Institute of Diagnostic Radiology, Friedrich–Alexander University of Erlangen–Nürnberg (FAU), Erlangen, Germany 4Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Evaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study

Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...

متن کامل

Defne Us Metal Artifact Reduction in Sinograms of Dental Computed Tomography

TAMPERE UNIVERSITY OF TECHNOLOGY International Master’s Degree Programme in Biomedical Engineering US, DEFNE: Metal Artifact Reduction in Sinograms of Dental Computed Tomography Master of Science Thesis, 70 pages, 4 Appendix pages May 2013 Major subject: Biomedical Engineering Examiners: Prof. Ulla Ruotsalainen Prof. Jari Viik M.Sc. Uygar Tuna

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012