Radio frequency (B1) field mapping at 7T using 3D SE/STE EPI technique

نویسندگان

  • A. Lutti
  • C. Hutton
  • J. Stadler
  • O. Josephs
  • O. Speck
  • C. Tempelmann
  • J. Bernarding
  • N. Weiskopf
چکیده

A. Lutti, C. Hutton, J. Stadler, O. Josephs, O. Speck, C. Tempelmann, J. Bernarding, and N. Weiskopf Wellcome Trust Centre for Neuroimaging, Institute of Neurology, University College London, London, United Kingdom, Special Lab Non-Invasive Brain Imaging, Leibniz Institute for Neurobiology, Magdeburg, Germany, Dept. Biomedical Magnetic Resonance, Institute for Experimental Physics, Otto-von-Guericke University, Magdeburg, Germany, Department of Neurology, Otto-von-Guericke University, Magdeburg, Germany, Institute for Biometry and Medical Informatics, Faculty of Medicine, Otto-von-Guericke-University, Magdeburg, Germany

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of 3D EPI technique for radio frequency (B1) field mapping at 3T

Introduction Spatial inhomogeneities in the radio-frequency (RF) field (B1) increase with field strength as the RF wavelength approaches the dimensions of the human head. B1 inhomogeneities pose various problems such as spurious signal and contrast changes in MRI, leading to bias in quantitative imaging and difficulties in tissue segmentation. Here, we optimize the 3D EPI B1 mapping method intr...

متن کامل

Robust and Fast Whole Brain Mapping of the RF Transmit Field B1 at 7T

In-vivo whole brain mapping of the radio frequency transmit field B(1) (+) is a key aspect of recent method developments in ultra high field MRI. We present an optimized method for fast and robust in-vivo whole-brain B(1) (+) mapping at 7T. The method is based on the acquisition of stimulated and spin echo 3D EPI images and was originally developed at 3T. We further optimized the method for use...

متن کامل

Optimization and group comparison of RF (B1) mapping methods at 3T

Introduction Spatial inhomogeneities in the radio-frequency (RF) field (B1) increase with field strength as the RF wavelength approaches the dimensions of the human head. B1 inhomogeneities pose various problems such as spurious signal and contrast changes in MRI, leading to bias in quantitative imaging and difficulties in tissue segmentation. Here, we optimize and compare three methods for fli...

متن کامل

Improved proton spectroscopy at 7T using localized B1 calibration

Introduction At high magnetic fields of 7 T and above there is a large variation of B1 over the subject due either to the sample-induced inhomogeneities and the frequent use of local Tx/Rx coils in the absence of a transmit body coil. Therefore, accurate tip angle calibration techniques are very important, and simple slice-selective methods which are normally used at lower field strengths can l...

متن کامل

Fast and Robust B1 Mapping at 7T by the Bloch-Siegert Method

Introduction: B1 mapping has a variety of applications including the design of RF pulses in parallel transmit systems, and flip angle calibration for T1 mapping. Many existing B1 mapping methods suffer from T1 dependence, long scan time or inability to handle the large B1 inhomogeneity that occurs even across the human brain at 7T. The Bloch-Siegert B1 mapping method has been recently introduce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009