Uninfected nonunion of the humeral diaphyses: review of 21 patients treated with shingling, compression plate, and autologous bone graft.

نویسندگان

  • R Bernard de Dompsure
  • R Peter
  • P Hoffmeyer
چکیده

INTRODUCTION Controversy continues around selecting the best strategy for managing nonunions of the humeral diaphysis. The objective of this retrospective study was to analyse the results of management of this complication using a uniform surgical technique. HYPOTHESIS The rate of union obtained in the present series is comparable to the results reported in the literature. PATIENTS AND METHODS Twenty-one patients were surgically treated at the Geneva University Hospital for nonunion of the humeral diaphysis between 1995 and 2005 with a mean follow up of 50 months. Open reduction and internal fixation in compression using plates and screws with autologous bone graft enhancement was used. Eight cases were revisions of nonunions following a closed orthopaedic treatment and 13 cases were revisions following a failed surgical treatment. RESULTS All the patients obtained union within a mean 4.5 months. The functional scores for the shoulder (Constant) and the elbow (Mayo) were 77 and 97 points (mean), respectively.Two patients developed transient paresis related to radial nerve and musculocutaneous nerve injuries and one had a recurring fracture. A single patient required a second intervention for delayed union. DISCUSSION Of the surgical techniques for managing nonunion of the humerus, plate osteosynthesis is the most widely used. This simultaneously allows anatomic reduction, fracture compression, and osteogenesis stimulation. However, it can lead to infectious complications(although absent in our series) and neurological complications (10% transitory paresis in our patients).We report 95% rapid union in our series. Other techniques such as intramedullary nailing and external fixation do not provide equivalent results, and this is in agreement with the data found in the literature. We therefore recommend using compression plate fixation associated with autologous bone graft for the treatment of established nonunion of the humeral shaft.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of 10 year humeral shaft nonunion with segment bony defect: a case report

Humeral shaft nonunions with severe osteopenia presents challenges. Because of previous surgeries, complex anatomy of vascular, muscles and nerves at the nonunion site making the operation difficulty and risky. Vascularized fibula transfer and bone transporting are particularly useful in handling bone loss. However both methods require surgical experience and facility which are not available in...

متن کامل

[Treatment of recalcitrant humeral nonunion in elderly patients].

BACKGROUND Humeral nonunion that persists through various unsuccessful attempts at management, presents a real challenge. When combined with severe osteoporosis in elderly patients, the problems only increase. This study aims to investigate the best option for treating this combination of factors. MATERIALS AND METHOD This study analyses the outcomes of five patients with the following inclus...

متن کامل

The role of autologous bone graft in surgical treatment of hypertrophic nonunion of midshaft clavicle fractures.

BACKGROUND This study was conducted to evaluate the results of treating hypertrophic nonunion of mid-shaft clavicle fracture with a limited contact dynamic compression plate (LC-DCP) without autologous cancellous bone graft. METHODS From 1995 to 2008, 51 cases of hypertrophic nonunion of mid-shaft clavicle fracture were managed with open reduction and internal fixation by LC-DCP without bone ...

متن کامل

Comparing the Effect of Reamed Exchange Nailing and Augmentation Compression Plating in Treatment of Femoral Shaft Nonunion

 Background and purpose: One of the most important complications of bone fractures is nonunion. This research aimed at comparing the effect of exchange nailing and plate augmentation on complications after surgery and the time to achieve desired outcomes. Materials and methods: This descriptive-analytical study was conducted in 12 femoral shaft nonunion cases treated operatively in 2011-2018 (...

متن کامل

Treatment of nonunion of humeral shaft fracture with dynamic compression plate and cancellous bone graft.

BACKGROUND This study was conducted to evaluate the treatment of aseptic nonunion of the humeral shaft with a dynamic compression plate (DCP) and cancellous bone graft. METHODS One hundred and five cases of nonunion of a humeral shaft fracture between 1982 and 2001 were analyzed retrospectively. The study population comprised 66 males and 39 females with an average age of 46.2 years (range, 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 96 2  شماره 

صفحات  -

تاریخ انتشار 2010