Comparison between a Conductometric Biosensor and ELISA in the Evaluation of Johne's Disease
نویسندگان
چکیده
Johne's disease (JD), caused by Mycobacterium avium subspecies paratuberculosis (MAP), is an important gastrointestinal disease of cattle worldwide because of the economic losses encountered in JD-affected herds. These losses include reduction in milk yield in cows, premature culling and reduced carcass weight of culled diseased animals. In the U.S. dairy industry, economic losses from reduced productivity associated with JD are estimated to cost between $200 and $250 million annually. The development of non-laboratory-based assays would support more frequent testing of animals for JD and could improve its control. Conductometric biosensors combine immunomigration technology with electronic signal detection and have been adapted for the detection of IgG antibody against MAP. In the present study, a capture membrane with limited variability in the immunomigration channel and an optimal concentration of the secondary anti-bovine antibody used in a previously developed conductometric biosensor were compared with a commercially available antibody detection ELISA in their evaluation of JD, using samples of serum from cattle whose JD status where unknown. There was a moderate strength of agreement (kappa = 0.41) between the two assays. Findings from this preliminary study support the continued development of conductometric biosensors for use in the diagnosis of JD.
منابع مشابه
Fabrication of a Novel Conductometric Biosensor for Detecting Mycobacterium avium subsp. paratuberculosis Antibodies
Johne's disease (JD) is one of the most costly bacterial diseases in cattle. In the U.S., economic losses from the disease have been estimated to exceed $1,500,000,000 per year, mainly from the effects of reduced milk production. Current diagnostic tests for JD are laboratory based and many of those tests require specialized equipment and training. Development of rapid and inexpensive diagnosti...
متن کاملA Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode
Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...
متن کاملComparison between conventional PCR and PCR - ELISA for detection of Brucella melitensis
Molecular detection techniques are believed to be key tools for both prevention and treatment follow up of brucellosis within live stock and human beings. Consequently rapid, reliable, easy to perform and automated systems for Brucella detection are urgently needed to allow early diagnosis and adequate antibiotic therapy in time. Brucellosis is a worldwide re-emerging zoonosis causing high econ...
متن کاملA bi-enzymatic whole cell conductometric biosensor for heavy metal ions and pesticides detection in water samples.
A conductometric biosensor using immobilised Chlorella vulgaris microalgae as bioreceptors was used as a bi-enzymatic biosensor. Algae were immobilised inside bovine serum albumin membranes reticulated with glutaraldehyde vapours deposited on interdigitated conductometric electrodes. Local conductivity variations caused by algae alkaline phosphatase and acetylcholinesterase activities could be ...
متن کاملJaw Cancer Detection Using Nano Amperometric Biosensor with Surface Tension Variables
1. Amperometric 2. Voltametric 3. Conductometric Biosensors [1]. In amperometric biosensor, current is final output, this current is measured in terms of oxygen. Whereas in Voltametric biosensor and voltage is final output. In conductometric biosensor, thermal voltage is final output. The biosensor contains a ligand and a transducer ligand means biological element and transducer mean which conv...
متن کامل