Innovative Methodology A simplified noninvasive method to measure airway blood flow in humans

نویسندگان

  • Adam Wanner
  • Eliana S. Mendes
  • Neal D. Atkins
چکیده

Wanner, Adam, Eliana S. Mendes, and Neal D. Atkins. A simplified noninvasive method to measure airway blood flow in humans. J Appl Physiol 100: 1674–1678, 2006; doi:10.1152/japplphysiol.01349.2005.— Our laboratory has previously developed and validated a noninvasive soluble gas uptake method to measure airway blood flow (Q̇aw) in humans (Onorato DJ, Demirozu MC, Breitenbücher A, Atkins ND, Chediak AD, and Wanner A. Am J Respir Crit Care Med 149: 1132–1137, 1994; Scuri M, McCaskill V, Chediak AD, Abraham WM, and Wanner A. J Appl Physiol 79: 1386–1390, 1995). The method has the disadvantage of requiring eight breath-hold maneuvers for a single Qaw measurement, a complicated data analysis, and the inhalation of a potentially explosive gas mixture containing dimethylether (DME) and O2. Because of these shortcomings, the method thus far has not been used in other laboratories. We now simplified the method by having the subjects inhale 500 ml of a 10% DME-90% N2 gas mixture to fill the anatomical dead space, followed by a 5or 15-s breath hold, and measuring the instantaneous DME and N2 concentrations and volume at the airway opening during the subsequent exhalation. From the difference in DME concentration in phase 1 of the expired N2 wash-in curve multiplied by the phase 1 dead space volume and divided by the mean DME concentration and the solubility coefficient for DME in tissue, Qaw can be calculated by using Fick’s equation. We compared the new method to the validated old method in 10 healthy subjects and found mean SE Q̇aw values of 34.6 2.3 and 34.6 2.8 l min 1 ml , respectively (r 0.93; upper and lower 95% confidence limit 2.48 and 2.47). Using the new method, the mean coefficient of variation for two consecutive measurements was 4.4% (range 0–10.4%); inhalation of 1.2 mg albuterol caused a 53 14% increase in Q̇aw (P 0.02) and inhalation of 2.4 mg methoxamine caused a 32 7% decrease in Q̇aw (P 0.07). We conclude that the new method provides reliable values of and detects the expected changes in Q̇aw with vasoactive drugs. The simplicity and improved safety of the method should improve its acceptability for the noninvasive assessment of Q̇aw in clinical research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simplified noninvasive method to measure airway blood flow in humans.

Our laboratory has previously developed and validated a noninvasive soluble gas uptake method to measure airway blood flow (Qaw) in humans (Onorato DJ, Demirozu MC, Breitenbücher A, Atkins ND, Chediak AD, and Wanner A. Am J Respir Crit Care Med 149: 1132-1137, 1994; Scuri M, McCaskill V, Chediak AD, Abraham WM, and Wanner A. J Appl Physiol 79: 1386-1390, 1995). The method has the disadvantage o...

متن کامل

Modal analysis of a turbo-pump shaft: An innovative suspending method to improve the results

Modal parameter extraction of high speed shafts is of critical importance in mechanical design of turbo-pumps. Due to the complex geometry and peripheral components of turbo-pumps, difficulties can arise in determination of modal parameters. In this study, modal properties of a turbo-pump shaft, was studied by experimental modal analysis, and using different excitation techniques. An innovative...

متن کامل

New modalities for non-invasive positive pressure ventilation: A review article

Efficiency of non-invasive positive pressure ventilation in the treatment of respiratory failure has been shown in many published studies. In this review article, we introduced new modalities of non-invasive ventilation (NIV), clinical settings in which NIV can be used and a practical summary of the latest official guidelines published by the European Respiratory Clinical Practice. Clinical tri...

متن کامل

Innovative Methodology Measuring peripheral resistance and conduit arterial structure in humans using Doppler ultrasound

Naylor, Louise H., Cara J. Weisbrod, Gerry O’Driscoll, and Daniel J. Green. Measuring peripheral resistance and conduit arterial structure in humans using Doppler ultrasound. J Appl Physiol 98: 2311–2315, 2005. First published February 3, 2005; doi:10.1152/japplphysiol.01047.2004.— The purpose of this study was to establish valid indexes of conduit and resistance vessel structure in humans by u...

متن کامل

Innovative Methodology Unrestrained video-assisted plethysmography: a noninvasive method for assessment of lung mechanical function in small animals

Bates JH, Thompson-Figueroa J, Lundblad LK, Irvin CG. Unrestrained video-assisted plethysmography: a noninvasive method for assessment of lung mechanical function in small animals. J Appl Physiol 104: 253–261, 2008. First published October 25, 2007; doi:10.1152/japplphysiol.00737.2007.—The assessment of lung mechanical function in small animals, particularly mice, is essential for investigation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006