Lung deposition patterns of directly labelled salbutamol in normal subjects and in patients with reversible airflow obstruction.

نویسندگان

  • R Melchor
  • M F Biddiscombe
  • V H Mak
  • M D Short
  • S G Spiro
چکیده

BACKGROUND--Earlier studies of aerosol deposition in the lungs have relied on indirect labelling of Teflon spheres of a similar size distribution to the drug in question and have assumed similar aerodynamic properties. Using a modification of a new technique for directly labelling salbutamol, the deposition of salbutamol within the lungs of normal subjects and patients with asthma has been studied with the use of a metered dose inhaler (MDI) alone, an MDI with a spacer device, and a dry powder inhaler (DPI). METHOD--Salbutamol was directly labelled with technetium-99m and placed in an MDI or DPI. Ten normal subjects and 19 patients with asthma inhaled 200 micrograms of salbutamol by means of the MDI alone, the MDI with a spacer device attached, and by DPI on separate days. Deposition was assessed by a dual headed gamma camera after inhalation of the drug. RESULTS--The total mean (SD) percentage deposition of the drug in the normal subjects was 21.6% (8.9%) with the MDI alone, 20.9% (7.8%) with the MDI with spacer, and 12.4% (3.5%) with the DPI. For the patients, the mean percentage deposition was 18.2% (7.8%) with the MDI alone, 19.0% (8.9%) with the MDI and spacer, and 11.4% (5.0%) with the DPI. Bronchodilatation achieved by the patients was similar with all three techniques. Mean peripheral lung deposition was significantly greater with a spacer device than when the MDI was used alone in both normal subjects (49.4% (6.1%) v 44.1% (9.9%)) and patients (38.6% (11.1%) v 30.4% (9.4%)). CONCLUSIONS--The deposition of directly labelled salbutamol from an MDI is greater than previously estimated by indirect labelling techniques. The deposition of labelled salbutamol from a DPI, however, is little different from that measured by indirect techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct labelling of ipratropium bromide aerosol and its deposition pattern in normal subjects and patients with chronic bronchitis.

A technique for the direct labelling of ipratropium bromide with bromine-77, with reconstitution of the drug in a metered dose inhaler so as to be identical to the commercial product, was used to study drug deposition patterns in seven normal subjects and seven patients with chronic bronchitis (mean FEV1 32% (SD 12.2%) predicted normal). The gamma camera image of the thorax was divided into a m...

متن کامل

Lipid Profile Status in Mustard Lung Patients and its Relation to Severity of Airflow Obstruction

Introduction: Chronic obstructive pulmonary disease (COPD) secondary to sulfur mustard gas poisoning, known as mustard lung, is a major late pulmonary complications in chemical warfare patients. Serious comorbidities like dyslipidemia are frequently encountered in COPD. The aim of this study was to measure the serum lipid profile and evaluate the relation of lipid parameters with the severity o...

متن کامل

Assessment of reversibility of airway obstruction in patients with chronic obstructive airways disease.

Spirometry before and after an inhaled beta agonist or a course of oral prednisolone is widely used to detect reversible airflow limitation in patients with chronic obstructive lung disease. How many of these patients have a response and how the response to beta agonists relates to the response to corticosteroids is not clear. In 127 outpatients (mean (SD) FEV1 0.92 (0.38) 1) who had a clinical...

متن کامل

The Relationship between the Severity of Airway Obstruction and COPD Diagnostic Questionnaire Score in COPD Patients

Background & objectives: Chronic obstructive pulmonary disease (COPD) is characterized by irreversible airflow limitation and systemic inflammation which is also associated with pulmonary and extra-pulmonary complications. COPD Diagnostic Questionnaire (CDQ) is a valid questionnaire that is used to identify patients with COPD. The purpose of this study was to determine the relationship between ...

متن کامل

Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution.

The lung dose and deposition patterns of drug delivered by dry powder inhaler are not known. The effects of inhaling 400 micrograms salbutamol delivered by dry powder inhaler (two 200 micrograms salbutamol Rotacaps), by pressurised metered dose inhaler, and by Acorn nebuliser were studied in nine subjects with chronic stable asthma. Technetium-99m labelled Teflon particles were mixed with micro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 48 5  شماره 

صفحات  -

تاریخ انتشار 1993