Leaflet Escape in a New Bileaflet Mechanical Valve
نویسنده
چکیده
Background—Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. Methods and Results—At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9610.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet’s pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. Conclusion—These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure. (Circulation. 2003;107:r89-r92.)
منابع مشابه
Leaflet escape in a new bileaflet mechanical valve: TRI technologies.
BACKGROUND Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. METHODS AND RESULTS At the University of Padua, between November 2000 an...
متن کاملAcute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.
BACKGROUND Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. METHODS A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years...
متن کاملDirect imaging of bileaflet mechanical valve behavior in the tricuspid position.
OBJECTIVE The optimal orientation of a bileaflet mechanical valve for tricuspid valve replacement (TVR) has not yet been determined. The aim of this study was to use fiberoptic cardioscopy to evaluate the effect of orientation of a mechanical valve implanted in the tricuspid position on bileaflet mechanical valve behavior. METHODS Twelve pigs (50-59 kg) underwent TVR with a St. Jude Mechanica...
متن کاملStructural analysis of a bileaflet mechanical heart valve prosthesis with curved leaflet
Structural analysis, especially the thickness effect on the structural strength, of a bileaflet mechanical heart valve prosthesis with curved leaflets is presented in this paper. Taking the wide variations of the blood flow pressure on the leaflet surface, the structural stresses inside the leaflet and deflections of the leaflet are investigated by adopting both linear and nonlinear structural ...
متن کاملRetrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.
The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwen...
متن کامل