Comparison of Contrast-Enhanced Isotropic 3D-GRE-T1WI Sequence versus Conventional Non-Isotropic Sequence on Preoperative Staging of Cervical Cancer

نویسندگان

  • Xiaoduo Yu
  • Meng Lin
  • Feng Ye
  • Han Ouyang
  • Yan Chen
  • Chunwu Zhou
  • Zihua Su
چکیده

PURPOSE To compare contrast-enhanced isotropic 3D-GRE-T1WI sequence vs. conventional non-isotropic sequence in terms of image quality, estimated signal-to-noise ratio (eSNR), relative tumor contrast and performance of cervical cancer staging. METHODS This retrospective study was approved by the institutional review board, and informed consent was waived. Seventy-one patients (47 ± 9.4 years), with pathologically-confirmed cervical cancer underwent axial contrast-enhanced 1 mm3 isotropic 3D-GRE-T1WI sequence (herein referred to Isotropy), and 3-mm-thick non-isotropic sagittal and coronal sequences. Image quality score, eSNR and relative contrast between tumor to myometrium, gluteal muscle, and fat respectively, were compared between 3-mm-thick reconstructed images from Isotropy and directly scanned non-isotropic images by paired t-test. Difference in tumor staging obtained from Isotropy and combined Three-planes including reconstructed axial images, directly scanned sagittal and coronal sequence were compared by McNemar test. RESULTS Both sequences showed similar image quality. Reconstructed images demonstrated higher eSNR, equal or lower relative tumor contrast compared with non-isotropic images. Compared with performing diagnosis on Three-planes, both reviewers showed higher accuracy when diagnosing vaginal invasion on Isotropy (p = 0.039 and 0.003, respectively). CONCLUSION Compared with non-isotropic sequence, 3.0T MR isotropic 3D-GRE-T1WI sequence exhibited better eSNR, providing more reliable clinical information for preoperative staging of cervical cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

Fast high resolution whole brain T2* weighted imaging using echo planar imaging at 7 T

Magnetic susceptibility based (T(2)* weighted) contrast in MRI at high magnetic field strength is of great value in research on brain structure and cortical architecture, but its use is hampered by the low signal-to-noise ratio (SNR) efficiency of the conventional spoiled gradient echo sequence (GRE) leading to long scan times even for a limited number of slices. In this work, we show that high...

متن کامل

Hepatic MR imaging with 3D Gradient Echo: Linear Cartesian k-space ordering with partial scan along both slice and phase direction

Introduction: 3D gradient echo (GRE) sequence is commonly used for T1-weighted MR imaging of liver. Conventional 3D GRE sequences utilize either one of centric-linear, radial or linear ordering of k-space with a fat suppression technique and partial scan technique along a slice direction. We introduce a enhanced 3D-GRE sequence, which adopted a linear ordering with half scan along both slice an...

متن کامل

Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: preliminary observations.

OBJECTIVE The purposes of this study were to evaluate the feasibility of a free-breathing 3D gradient-recalled echo sequence with radial data sampling (radial 3D GRE) in abdominal MRI compared with a standard 3D GRE volumetric interpolated breath-hold examination (VIBE) sequence for imaging of cooperative patients and to perform a preliminary assessment in imaging of noncooperative patients. ...

متن کامل

Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist

BACKGROUND Our study was performed to evaluate the image quality of 3 T MR wrist arthrograms with attention to ulnar wrist structures, comparing image quality of isotropic 3D proton density fat suppressed turbo spin echo (PDFS TSE) sequence versus standard 2D 3 T sequences as well as comparison with 1.5 T MR arthrograms. METHODS Eleven consecutive 3 T MR wrist arthrograms were performed and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015