Increased peritoneal dialysis exit site infections using topical antiseptic polyhexamethylene biguanide compared to mupirocin: results of a safety interim analysis of an open-label prospective randomized study.

نویسندگان

  • Andrew Findlay
  • Charelle Serrano
  • Sally Punzalan
  • Stanley L Fan
چکیده

Prophylactic mupirocin for peritoneal catheter exit sites reduces exit site infection (ESI) risk but engenders antibiotic resistance. We present early interim safety analysis of an open-label randomized study comparing polyhexamethylene biguanide (PHMB) and mupirocin. A total of 106 patients randomized to 53 in each group were followed up for a mean of 12.68 months per patient. On safety analysis, the PHMB group had a significantly greater ESI rate than the mupirocin group (odds ratio [OR], 0.26; 95% confidence interval [CI], 0.09 to 0.80), leading to discontinuation of the trial.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The honeypot study protocol: a randomized controlled trial of exit-site application of medihoney antibacterial wound gel for the prevention of catheter-associated infections in peritoneal dialysis patients.

OBJECTIVES The primary objective of this study is to determine whether daily exit-site application of standardized antibacterial honey (Medihoney Antibacterial Wound Gel; Comvita, Te Puke, New Zealand) results in a reduced risk of catheter-associated infections in peritoneal dialysis (PD) patients compared with standard topical mupirocin prophylaxis of nasal staphylococcal carriers. DESIGN Mu...

متن کامل

A randomized controlled trial of topical exit site mupirocin application in patients with tunnelled, cuffed haemodialysis catheters.

BACKGROUND Central venous catheters are frequently needed for the provision of haemodialysis, but their clinical usefulness is severely limited by infectious complications. The risk of such infections can be reduced by topical application of mupirocin to the exit sites of non-cuffed catheters or by the use of tunnelled, cuffed catheters. Whether mupirocin offers any additional protection agains...

متن کامل

Comparison of gentamicin and mupirocin in the prevention of exit-site infection and peritonitis in peritoneal dialysis.

Exit-site infection (ESI) and peritonitis are the most frequent reasons for catheter removal and patient drop-out from peritoneal dialysis (PD). After a randomized double-blind study showed gentamicin to be superior to mupirocin for exit-site prophylaxis, several dialysis centers including ours switched from topical mupirocin to gentamicin. Our study examined whether the change from mupirocin t...

متن کامل

Exit-Site Dressing and Infection in Peritoneal Dialysis: A Randomized Controlled Pilot Trial.

UNLABELLED ♦ OBJECTIVE Peritoneal dialysis (PD)-related infection is a common cause of catheter loss and the main reason for PD drop-out. Exit-site infection (ESI) is a pathway to developing tunnel infection and peritonitis, hence rigorous exit-site care has always been emphasized in PD therapy. The aim of this study was to evaluate the effect of exit-site dressing vs non-dressing on the rate...

متن کامل

Clinical effectiveness of different approaches to peritoneal dialysis catheter exit-site care.

OBJECTIVE The objective of this review was to appraise and synthesise the best available evidence on the clinical effectiveness of peritoneal dialysis catheter exit-site care. INCLUSION CRITERIA This review considered all randomised controlled trials that evaluated the effectiveness of peritoneal exit-site care. In the absence of randomised controlled trials, other controlled research designs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 2013