Soft X-ray detection and photon counting spectroscopy with commercial 4H-SiC Schottky photodiodes

نویسنده

  • S. Zhao
چکیده

The results of electrical characterisation and X-ray detection measurements of two different active area (0.06 mm and 0.5 mm) commercial 4H-SiC Schottky photodiodes at room temperature are reported. The devices exhibited low dark currents (less than 10 pA) even at a high electric field strengths (403 kV/ cm for 0.06 mm diodes; 227 kV/cm for 0.5 mm diodes). The results of the X-ray measurements indicate that the diodes can be used as photon counting spectroscopic X-ray detectors with modest energy resolutions: FWHM at 5.9 keV of 1.8 keV and 3.3 keV, for the 0.06 mm and 0.5 mm devices, respectively. Noise analysis of the photodiodes coupled to a custom low noise charge sensitive preamplifier is also presented. & 2016 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Full-band Monte Carlo simulation of high-energy carrier transport in single photon avalanche diodes: Computation of breakdown probability, time to avalanche breakdown, and jitter

Related Articles Ultra-low noise single-photon detector based on Si avalanche photodiode Rev. Sci. Instrum. 82, 093110 (2011) GaN/SiC avalanche photodiodes Appl. Phys. Lett. 99, 131110 (2011) Influence of the metallic contact in extreme-ultraviolet and soft x-ray diamond based Schottky photodiodes J. Appl. Phys. 110, 054513 (2011) Organic position sensitive photodetectors based on lateral donor...

متن کامل

X-ray spectrometer with a low-cost SiC photodiode

A low-cost Commercial-Off-The-Shelf (COTS) 4H-SiC 0.06 mm2 UV p-n photodiode was coupled to a low-noise charge-sensitive preamplifier and used as photon counting X-ray spectrometer. The photodiode/spectrometer was investigated at X-ray energies from 4.95 keV to 21.17 keV: a Mo cathode X-ray tube was used to fluoresce eight high-purity metal foils to produce characteristic X-ray emission lines w...

متن کامل

Plasma characterization of the gas-puff target source dedicated for soft X-ray microscopy using SiC detectors

Extreme ultraviolet (EUV) and soft X-ray (SXR) radiations have a wide range of scientifi c [1], biomedical [2], and industrial applications [3]. For these reasons, monitoring the radiation parameters on line, such as the energy, intensity, angular distribution and reproducibility becomes very important. Semiconductor detectors play an important role due to their high sensitivity, linearity and ...

متن کامل

Al0.2Ga0.8As X-ray photodiodes for X-ray spectroscopy

Three custom-made Al0.2Ga0.8As p-i-n mesa X-ray photodiodes (200 μm diameter, 3 μm i layer) were electrically characterised and investigated for their response to illumination with soft X-rays from an Fe radioisotope X-ray source (Mn Kα = 5.9 keV; Mn Kβ = 6.49 keV). The AlGaAs photodiodes were shown to be suitable for photon counting X-ray spectroscopy at room temperature. When coupled to a cus...

متن کامل

Demonstration of 4H-SiC UV single photon counting avalanche photodiode - Electronics Letters

Introduction: Single photon counting detectors enable the receiver of an optoelectronic system to achieve the ultimate receiver sensitivity, the quantum limit. They are also essential in applications that rely on the quantum nature of the light, such as quantum cryptography and quantum computing. Photomultiplier tubes (PMTs) are commonly used for single photon counting because of its high gain ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016