Testing electrode suitability for field stimulation of high-threshold biological preparations

نویسندگان

  • Hugo Fernando Maia Milan
  • Rosana Almada Bassani
  • José Wilson Magalhães Bassani
چکیده

Introduction: A problem posed by electrical field (E) stimulation of biological preparations with high excitation threshold is that the E intensity required for excitation is likely to induce water electrolysis at the electrode surface, which can alter the extracellular medium and cause deleterious effects on the cells. In this study, different electrode materials and geometries were tested aiming at identifying electrode configurations that could transduce the E intensity required for exciting ventricular cardiomyocytes isolated from neonatal rats (threshold E ~30 V/cm) without causing water electrolysis. Methods: Wire and plate electrodes made of platinum, stainless steel and nickel/chrome alloy were used. The effect of blasting the electrode surface with sand and NaHCO3 solution was also tested. Electrodes were inserted into a cell perfusion chamber containing the saline solution routinely used for physiological experiments. During E application for 5 min, the electrode surface and its surroundings were examined at high magnification for the presence of microbubbles, which indicates the occurrence of water electrolysis. The greatest E intensity applied that failed to generate microbubbles (En) was estimated. Results: While nickel/chrome and stainless steel electrodes resulted in low En values, the best performance was observed for sandblasted platinum wire (2 mm diameter) and plate (25 mm x 5 mm; 0.1 mm thickness) electrodes, for which En was ≥40 V/cm. Conclusion: These electrode configurations are suitable for effective and safe stimulation of isolated neonatal cardiomyocytes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ENDOGENOUS RELEASE OF OPIATES BY REPETITIVE ELECTRICAL FIELD STIMULATION IN THE GUINEA-PIG AND RAT ILEAL LONGITUDINAL MUSCLE

The effect of repetitive electrical field stimulation and the response of the guinea-pig and rat ileal longitudinal muscle to single pulse stimulations was examined. Single pulse field stimulation produced twitch contraction which was inhibited by repetitive field stimulation (10 Hz, 40V, 0.5 msec for 5 m). This inhibition was largely, though never completely, reversed by naloxone. Contrac...

متن کامل

Asymmetric Rectangular Waveform in Stimulation with High Frequency Alternating Current Reduces the Threshold for Neural Conduction Block

Introduction Abnormal neural impulses in the nervous system may lead to various diseases and disabilities. High frequency alternating currents (HFAC) has been used to block the propagation of such impulses and improve the symptoms or disabilities. The technique is safe, reversible, and relatively selective, and its reliability, the optimum stimulation parameters, and elimination of the onset re...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

High-amplitude electrical stimulation can reduce elicited neuronal activity in visual prosthesis

Retinal electrostimulation is promising a successful therapy to restore functional vision. However, a narrow stimulating current range exists between retinal neuron excitation and inhibition which may lead to misperformance of visual prostheses. As the conveyance of representation of complex visual scenes may require neighbouring electrodes to be activated simultaneously, electric field summati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015