Breakage of Needle during Intracavernosal Injection and Use of Portable Ultrasound Guidance for Removal
نویسندگان
چکیده
Purpose. Intracavernosal self-injection (ICI) was first described in 1982, and remains a viable therapy for erectile dysfunction. However, intracorporal needle breakage can be a rare complication of therapy. We report a rare complication of intracorporal needle breakage and a retention of a 30-gauge needle in a 42-year-old paraplegic man. We discuss our experience in using portable high-frequency ultrasound intraoperatively to visualize and guide removal of a retained ICI needle. Materials and Methods. Review of case and ultrasound technique are presented. Results. Using intraoperative ultrasound imaging, the retained intracorporal needle was successfully removed from the patient's penis without any complications. Follow-up ultrasonography and X-ray confirmed complete removal of the needle. Conclusions. We report on the successful implementation and use of a portable high-frequency ultrasound probe to visualize a retained intracorporal needle inside the penis and its use to guide removal. Given the rapid proliferation of portable ultrasound machines in the operating room and out in the field, we expect these imaging techniques to become routine, especially in urological emergencies.
منابع مشابه
Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique
Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulat...
متن کاملUltrasound-guided epidural blood patch.
A 35-YR-OLD woman presented with a postdural puncture headache for epidural blood patch. The procedure was performed in the lateral position. A curvilinear ultrasound probe with sterile cover was used to visualize the epidural space. A 20-G epidural needle was used to identify the space by the loss-of-resistance technique. Blood was then injected into the epidural space under real-time ultrasou...
متن کاملFacilitating needle alignment in-plane to an ultrasound beam using a portable laser unit.
OBJECTIVE Ultrasound guidance can increase success with peripheral nerve blocks. Accurate anesthetic injection is optimized with both clear visualization and fine adjustment of the needle tip at the target area. Good needle alignment with the ultrasound beam and using a freehand technique are both desirable for these conditions. The purpose of this report is to describe how a unique, in-plane l...
متن کاملبلوک شبکه عصبی براکیال با هدایت اولتراسوند: بررسی 30 مورد
Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...
متن کاملThe Effects of Ultrasound-Guided Dry Needling on Patients With Myofascial Pain Syndrome: A Review Study
Objectives: Dry Needling (DN) is a novel and effective intervention for patients with Myofascial Pain Syndrome (MPS). Some characteristics, such as needle penetration depth, needle insertion into the target muscle, and trigger points must be identified in this intervention. The Ultrasound (US)-guided DN is a technique that involves needle insertion at the site of injury and the simulation of ti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013