Effects of Contrast Agent and Outer Volume Saturation Bands on Water Suppression and Shimming of Hepatic Single-Volume Proton MR Spectroscopy at 3.0T

نویسندگان

  • Li Xu
  • Yan Huang
  • Xian Liu
  • Bo Liu
چکیده

PURPOSE To determine whether administration of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and whether placement of the outer volume saturation bands significantly affect shimming and water suppression on hepatic MR spectroscopic prescanning. METHOD Region of interest (ROI) of 2 cm × 2 cm × 2 cm was carefully positioned in the region of the middle portion of the right hepatic lobe. 32 patients were examined before and after administration of Gd-DTPA with and without outer-volume saturation bands. Linewidths (Full-Width Half-Maximum (FWHM)) and water suppression were obtained. A paired t-test for comparison of means was used. RESULTS (1) The group with the outer volume saturation bands demonstrated slightly better water suppression effect than the group without outer volume saturation bands before administration. (2) The group with the outer volume saturation bands demonstrated better water suppression effect than the group without outer volume saturation bands after administration. (3) Both shimming and water suppression effects were decreased on enhanced MR spectroscopic prescanning (all P < 0.05). CONCLUSIONS Placement of the outer volume saturation bands is helpful to improve water suppression both before and after contrast agent administration. Gd-DTPA exerts a slightly adverse effect (a statistically significant but clinically unimportant) on magnetic resonance spectroscopic prescanning at 3T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost function guided 3order B0 shimming for MR spectroscopic imaging at 7T

Introduction At high field strengths, shimming becomes increasingly more difficult and important since susceptibility induced B0 inhomogeneities increase. Exploiting up to 3 rd order shim coils on the system, a high number of degrees of freedom are available to generate a more homogeneous B0 field. In MR spectroscopy excellent shimming is an important factor for acquiring high quality data sinc...

متن کامل

Automatic placement of outer volume suppression slices in MR spectroscopic imaging of the human brain.

Spatial suppression of peripheral regions (outer volume suppression) is used in MR spectroscopic imaging to reduce contamination from strong lipid and water signals. The manual placement of outer volume suppression slices requires significant operator interaction, which is time consuming and introduces variability in volume coverage. Placing a large number of outer volume saturation bands for v...

متن کامل

H Magnetic Resonance Spectroscopy of Cystic Ovarian Lesions

Most female ovarian lesions manifest as cystic masses contain variable contents of fluid. MR image is increasingly used to evaluate theses cystic lesions; malignancy can in some cases be predicted, however, sometimes it is nonspecific for differentiation of benign and malignant lesions. Solid component of ovarian cystic tumors visualized on ultrasonography, CT or MR images strongly supports the...

متن کامل

In vivo 1 H NMR spectroscopy of the developing rat hippocampus

Methods: Neonatal rats (n = 5, 7-28 days old) were anesthetized by -chloralose and fixed to a specifically designed holder. The volume of interest (3 x 2 x 4 mm) was centered in the left hippocampus. H NMR spectra were measured at 400 MHz (9.4T) on a Varian/Magnex spectrometer using an ultra-short echo-time STEAM sequence (TE = 2 ms) with VAPOR water suppression and outer volume saturation [5]....

متن کامل

MRS Shimming: An Important Point Which Should not be Ignored

Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012