Performance study on solar assisted heat pump water heater using CO2 in a transcritical cycle

نویسندگان

  • M. Raisul Islam
  • Samee Ullah Khan
چکیده

This study reports the numerical analyses of a CO2 transcritical cycle on solar assisted heat pump water heating system in which evacuated tube U-pipe solar collector is utilized as an evaporator. This simulation model can predict operating characteristics for moderate meteorological conditions of North Dakota. The main purpose of this work is to simulate the overall performance of the heat pump cycle by varying compressor speed. From the analysis the coefficient of performance (COP) value is predicted from 1.5 – 2.8 with three different average solar insolation. The results showed that the performance of the system significantly influenced by the compressor speed and solar irradiation. This study also calculated the instantaneous collector efficiency and found in the range of 50 – 55%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater

Besides compressor rotary speed and parameters of water flowing through gas cooler and evaporator, refrigerant charge amount and electronic expansion valve (EEV) opening are two important parameters that have significant effects on the performance of a transcritical CO2 heat pump system. In this study, the effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump ...

متن کامل

Field Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control

Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...

متن کامل

Experimental Investigation on the Influence of Refrigerant Charge on the Performance of Trans-critical CO2 Water-Water Heat Pump

For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporat...

متن کامل

Experimental investigation on the influencing factors of a transcritical CO2 heat pump

As one of the earliest natural refrigerants, CO2 has a lot of unique advantages, such as zero ODP, negligible GWP, excellent heat transfer coefficient, high volumetric capacity, non-toxicity, non-flammability, and cost effectiveness. Since it was proposed to applying in the mobile air-conditioning, the transcritical CO2 cycle has been attracting great attentions to replace CFC and HCFC refriger...

متن کامل

Energy Consumption and Heat Storage in a Solar Greenhouse: Artificial Neural Network Method

In this study, the performance of a solar greenhouse heating system equipped with a linear parabolic concentrator and a dual-purpose flat plate solar collector‏ was investigated using the Artificial Neural Network (ANN) method. The heat required for the greenhouse at night hours was supplied by the heat stored in the storage tank by the solar system during the sunshine time and  an auxiliary he...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012