Wear of CoCrMo alloys used in metal-on-metal hip joints A tribocorrosion appraisal

نویسندگان

  • Stefano Mischler
  • Anna Igual Muñoz
چکیده

A good biocompatibility, excellent mechanical properties and high corrosion resistance characterize CoCrMo alloys. Therefore they are widely used for artificial joints in biomedical implants. However, the degradation of the implants during service life leads to the release into the body of toxic ions and wear particles. This continuous degradation is of concern for long-term stability of the implants. Published literature has highlighted the relevance of lubrication as well as metallurgical and contact mechanical factors on the degradation of CoCrMo implant alloys. Recent experimental investigations have proposed tribocorrosion, i.e., the interplay of mechanical wear and corrosion by the body fluids, as one of the crucial degradation mechanism of implants. Tribocorrosion is sub-discipline of tribology and corrosion that recently made significant progresses in mechanistic understanding and modelling. The present work aims at evaluating published results on the degradation of CoCrMo alloys using existing tribocorrosion concepts. Results show that wear accelerated corrosion due to mechanical removal of the passive film during sliding is a major contribution to the overall degradation. Further, a transition from low (10 N/mm m) to high (10 N/mm m) wear coefficients was found at a threshold electrode potential close to 0.2 VSHE These findings clearly show that electrochemical phenomena play a key role on the tribological behaviour of biomedical CoCrMo alloy implants. & 2012 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review

Orthopedic implants first started out as an all-metal hip joint replacement. However, poor design and machinability as well as unsatisfactory surface finish subjected the all-metal joint replacement to being superseded by a polyethylene bearing. Continued improvement in manufacturing techniques together with the reality that polyethylene wear debris can cause hazardous reactions in the human bo...

متن کامل

Wear mapping of CoCrMo alloy in simulated bio-tribocorrosion conditions of a hip prosthesis bearing in calf serum solution.

Wear maps were developed following a series of micro-abrasion-corrosion testing during idealised hip contact conditions for a CoCrMo alloy in a foetal calf serum solution. The main aim of the study was to characterise wear-corrosion or bio-tribocorrosion regimes of the alloy over a range of applied loads and applied potentials. The transitioning micro-abrasion-corrosion mechanisms, synergisms a...

متن کامل

Wear-Corrosion Synergism Influences the Performance of High-Carbon and Low-Carbon CoCrMo

INTRODUCTION Recently, the popularity of Metal-on-Metal (MoM) hip bearings have diminished due to the concerns with generated wear debris and metal ion release that cause a negative response in the surrounding tissues. MoM bearings are typically manufactured from two types of metal alloys, lowcarbon (LC) and high-carbon (HC) CoCrMo. However, little is known about the in-vivo behavior of the two...

متن کامل

Tribocorrosion of Pulsed Plasma-Nitrided CoCrMo Implant Alloy

In the present study, a forged CoCrMo (ISO 5832-12) has been subjected to pulsed plasma treatment in a N2/H2 atmosphere at low temperatures (below 500 C). This treatment resulted in the formation of a layer composed by dispersed chromium nitride particles in a N-enriched metal matrix. The materials were tested for corrosion and tribocorrosion performance in 0.9 wt% NaCl at room temperature unde...

متن کامل

An Investigation of LENS®-Deposited Medical-Grade CoCrMo Alloys

A series of deposition experiments using CoCrMo were performed using an Optomec LENS® machine. An analysis of hardness, microstructure, and wear trends of the deposited alloys was undertaken in an attempt to determine the applicability of using LENS® to create better materials for orthopedic implants. It was found that LENS®-deposited CoCrMo alloys were harder than wrought materials, however in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012