Comparison of T1 mapping techniques for ECV quantification. Histological validation and reproducibility of ShMOLLI versus multibreath-hold T1 quantification equilibrium contrast CMR

نویسندگان

  • Marianna Fontana
  • Steve K White
  • Sanjay M Banypersad
  • Daniel M Sado
  • Viviana Maestrini
  • Andrew S Flett
  • Stefan K Piechnik
  • Stefan Neubauer
  • Neil Roberts
  • James C Moon
چکیده

BACKGROUND Myocardial extracellular volume (ECV) is elevated in fibrosis or infiltration and can be quantified by measuring the haematocrit with pre and post contrast T1 at sufficient contrast equilibrium. Equilibrium CMR (EQ-CMR), using a bolus-infusion protocol, has been shown to provide robust measurements of ECV using a multibreath-hold T1 pulse sequence. Newer, faster sequences for T1 mapping promise whole heart coverage and improved clinical utility, but have not been validated. METHODS Multibreathhold T1 quantification with heart rate correction and single breath-hold T1 mapping using Shortened Modified Look-Locker Inversion recovery (ShMOLLI) were used in equilibrium contrast CMR to generate ECV values and compared in 3 ways.Firstly, both techniques were compared in a spectrum of disease with variable ECV expansion (n=100, 50 healthy volunteers, 12 patients with hypertrophic cardiomyopathy, 18 with severe aortic stenosis, 20 with amyloid). Secondly, both techniques were correlated to human histological collagen volume fraction (CVF%, n=18, severe aortic stenosis biopsies). Thirdly, an assessment of test:retest reproducibility of the 2 CMR techniques was performed 1 week apart in individuals with widely different ECVs (n=10 healthy volunteers, n=7 amyloid patients). RESULTS More patients were able to perform ShMOLLI than the multibreath-hold technique (6% unable to breath-hold). ECV calculated by multibreath-hold T1 and ShMOLLI showed strong correlation (r(2)=0.892), little bias (bias -2.2%, 95%CI -8.9% to 4.6%) and good agreement (ICC 0.922, range 0.802 to 0.961, p<0.0001). ECV correlated with histological CVF% by multibreath-hold ECV (r(2)= 0.589) but better by ShMOLLI ECV (r(2)= 0.685). Inter-study reproducibility demonstrated that ShMOLLI ECV trended towards greater reproducibility than the multibreath-hold ECV, although this did not reach statistical significance (95%CI -4.9% to 5.4% versus 95%CI -6.4% to 7.3% respectively, p=0.21). CONCLUSIONS ECV quantification by single breath-hold ShMOLLI T1 mapping can measure ECV by EQ-CMR across the spectrum of interstitial expansion. It is procedurally better tolerated, slightly more reproducible and better correlates with histology compared to the older multibreath-hold FLASH techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracellular matrix expansion by cardiac magnetic resonance T1 mapping- validation with myocardial biopsy

Background Accumulation of diffuse myocardial fibrosis / extracellular volume (ECV) in the myocardium is common to various cardiac diseases and is associated with an unfavorable prognosis. Various cardiac magnetic resonance (CMR) T1 mapping techniques have recently been proposed for the quantification of ECV, including: 1. Modified Look-Locker Inversion recovery (MOLLI) T1 mapping including cal...

متن کامل

Reproducibility of multiple T1 Mapping techniques and to ECV quantification

Background T1 Mapping has emerged as a new marker to quantify myocardial extracellular volume (ECV), which is typically increased in the setting of diffuse fibrosis or infiltrative heart diseases. However the reproducibility of the technique is largely unknown. We sought to identify the interobserver, intraobserver variability of different T1 mapping techniques as well as validation of one tech...

متن کامل

Letter by Iles and Taylor regarding article, "Comprehensive validation of cardiovascular magnetic resonance techniques for the assessment of myocardial extracellular volume".

BACKGROUND Extracellular matrix expansion is a key element of ventricular remodeling and a potential therapeutic target. Cardiovascular magnetic resonance (CMR) T1-mapping techniques are increasingly used to evaluate myocardial extracellular volume (ECV); however, the most widely applied methods are without histological validation. Our aim was to perform comprehensive validation of (1) dynamic-...

متن کامل

T1 mapping for myocardial extracellular volume measurement by CMR: bolus only versus primed infusion technique.

OBJECTIVES The aim of this study was to determine the accuracy of the contrast "bolus only" T1 mapping cardiac magnetic resonance (CMR) technique for measuring myocardial extracellular volume fraction (ECV). BACKGROUND Myocardial ECV can be measured with T1 mapping before and after contrast agent if the contrast agent distribution between blood/myocardium is at equilibrium. Equilibrium distri...

متن کامل

Histological Validation of measurement of diffuse interstitial myocardial fibrosis by myocardial extravascular volume fraction from Modified Look-Locker imaging (MOLLI) T1 mapping at 3 T

BACKGROUND Gadolinium (Gd) Extracellular volume fraction (ECV) by Cardiovascular Magnetic Resonance (CMR) has been proposed as a non-invasive method for assessment of diffuse myocardial fibrosis. Yet only few studies used 3 T CMR to measure ECV, and the accuracy of ECV measurements at 3 T has not been established. Therefore the aims of the present study were to validate measurement of ECV by MO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012