Low False Positive Rate of Kepler Candidates Estimated from a Combination of Spitzer and Follow-up Observations

نویسندگان

  • David Charbonneau
  • Guillermo Torres
  • François Fressin
  • Sarah Ballard
  • Stephen T. Bryson
  • Heather A. Knutson
  • Jean-Michel Désert
  • Natalie M. Batalha
  • William J. Borucki
  • Timothy M. Brown
  • Eric B. Ford
  • Jonathan J. Fortney
  • Ronald L. Gilliland
  • David W. Latham
  • Sara Seager
چکیده

NASA’s Kepler mission has provided several thousand transiting planet candidates during the four years of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) amongst the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false-positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5-40%, depending on the KOIs. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated by the Kepler observations, provides an independent indication that Kepler ’s false positive rate is low. Subject headings: planetary systems — transits — techniques: photometry

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Constraining the false positive rate for Kepler planet candidates with multicolour photometry from the GTC

Using the Optical System for Imaging and low Resolution Integrated Spectroscopy (OSIRIS) instrument installed on the 10.4-m Gran Telescopio Canarias (GTC), we acquired multicolour transit photometry of four small (Rp 5 R⊕) short-period (P 6 d) planet candidates recently identified by the Kepler space mission. These observations are part of a programme to constrain the false positive rate for sm...

متن کامل

A Catalog of Kepler Habitable Zone Exoplanet Candidates

The NASA Kepler mission ha s discovered thousands of new planetary candidates, many of which have been confirmed through follow-up observations. A primary goal of the mission is to determine the occurrence rate of terrestrial-size planets within the Habitable Zone (HZ) of their host stars. Here we provide a list of HZ exoplanet candidates from the Kepler Q1–Q17 Data Release 24 data-vetting proc...

متن کامل

The prevalence of adverse obstetric outcomes follow of an abnormal maternal serum AFP and NTDs screen positive group

Introduction: Prenatal maternal serum AFP screening tests have some inherent false positive and false negative results. For NTDs Screening test (FTS) false positive rate (FPR) is about 1% and false negative rate (FNR) is 20%. A false positive result encourages by Anomaly scan and invasive diagnostic procedures (that poses lots of stress on women, too), while a false negative result lead to a N...

متن کامل

A New Method for Detecting Sperms in Microscopy Images: Combination of Zernike Moments and Spatial Processing

Introduction: In recent years, modern microscopic imaging in parallel with digital image processing techniques, have facilitated computerized semen analysis. However, in these methods, distinguishing sperms from other semen particles can be hampered by low contrast of microscopic images and the possibility of neighboring sperms touching each other. Materials and Methods: This article introduced...

متن کامل

Automatic Sperm Analysis in Microscopic Images of Human Semen: Segmentation Using Minimization of Information Distance

Introduction The morphologic features of human sperms are key indicators for monitoring fertility problems in men. Therefore, automated analyzing methods via microscopic videos have become the most favorite policy in infertility treatment during the last decades. Materials and Methods In the proposed method, firstly a hypothesis testing framework was defined to distinguish sperms from backgroun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015