Quantiferon Gold-in-tube assay for TB screening in HIV infected children: influence of quantitative values
نویسندگان
چکیده
BACKGROUND HIV infected children are at increased risk of TB disease and require annual TB screening. Data on use of IGRA for TB screening in them are limited. We retrospectively evaluated the usefulness of Quantiferon Gold-in-tube test (QFT), an IGRA in screening for LTBI in relatively healthy, immunologically stable HIV infected children. METHODS HIV infected children with no prior history of TB were screened for latent TB as part of routine care. They underwent risk of TB assessment, TST and QFT. QFT was repeated twice or three times depending on the quantitative values. Independent test validation was also performed. RESULTS Eighty one children had 109 QFT tests. All had adequate mitogen responses. The initial QFT was positive in 15 (18.5%) children; quantitative IGRA responses were 0.35-1.0 IU/mL in 9 (60%), 1.0-10 IU/mL in5 (33.3%) and >10 IU/mL in 1 (6.7%). None that tested positive had documented TB exposure or TB disease. Baseline characteristics in the QFT positive and negative groups were similar. Repeat testing within 17 weeks demonstrated reversion to negative in 79% of cases. Repeat blinded independent testing of all QFT positive results and a random selection of initial negative tests demonstrated concordance in 96% of cases. Seven children (QFT > 1.0 IU/mL or positive TST) were offered INH preventive therapy. In no case has TB disease developed in 2 years of close follow-up. CONCLUSIONS QFT is a valid method for LTBI screening relatively healthy, immunologically stable HIV infected children. However, reversion to negative on repeat testing and lack of correlation with TST results and risk of TB exposure makes interpretation difficult.
منابع مشابه
Identification of false-positive QuantiFERON-TB Gold In-Tube assays by repeat testing in HIV-infected patients at low risk for tuberculosis.
The QuantiFERON-TB Gold In-Tube assay (QFT) is increasingly being used for latent tuberculosis screening in patients infected with human immunodeficiency virus (HIV) in the United States. This is a retrospective analysis of repeating positive QFT assays as a strategy to identify false-positive results in HIV-infected patients at low risk for tuberculosis.
متن کاملContribution of a heparin-binding haemagglutinin interferon-gamma release assay to the detection of Mycobacterium tuberculosis infection in HIV-infected patients: comparison with the tuberculin skin test and the QuantiFERON®-TB Gold In-tube
BACKGROUND The screening and treatment of latent tuberculosis (TB) infection reduces the risk of progression to active disease and is currently recommended for HIV-infected patients. The aim of this study is to evaluate, in a low TB incidence setting, the potential contribution of an interferon-gamma release assay in response to the mycobacterial latency antigen Heparin-Binding Haemagglutinin (...
متن کاملQuantiFERON-TB Gold and Tuberculin Skin Test for the Diagnosis of Latent Tuberculosis Infection in Children
Background: Appropriate diagnosis and treatment of latent tuberculosis infection (LTBI) play the most important role in the control of tuberculosis. This study aimed to determine the prevalence of LTBI among healthy tuberculosis unexposed children vaccinated with BCG using the tuberculin skin test (TST) and QuantiFERON TB Gold In-Tube (QFT-GIT) and comparing the agreement between the two tests....
متن کاملPopulation tailored modification of tuberculosis specific interferon-gamma release assay
OBJECTIVES Blood-based Interferon-Gamma Release Assays (IGRA) identify Mycobacterium tuberculosis (MTB) sensitisation with increased specificity, but sensitivity remains impaired in human immunodeficiency virus (HIV) infected persons. The QuantiFERON-TB Gold In-Tube test contains peptide 38-55 of Rv2654c, based on data indicating differential recognition between tuberculosis patients and BCG va...
متن کاملAccuracy of the QuantiFERON-TB Gold in Tube for diagnosing tuberculosis in a young pediatric population previously vaccinated with Bacille Calmette-Guérin
OBJECTIVE To evaluate the accuracy of an interferongamma release assay (QuantiFERON-TB Gold in Tube) for diagnosing Mycobacterium tuberculosis infection in a young pediatric population. METHODS 195 children previously vaccinated with BCG were evaluated, being 184 healthy individuals with no clinical or epidemiological evidence of mycobacterial infection, and 11 with Mycobacterium tuberculosis...
متن کامل