Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers

نویسندگان

  • Y. D. Tu
  • R. Z. Wang
  • T. S. Ge
  • X. Zheng
چکیده

Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump's efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis on Parameters of Regeneration Subsystem in Liquid Desiccant Dehumidification Systems

Along with the widely use in industries and lives, the dehumidification systems have consumed a large amount of energy. Fortunately, the application of liquid desiccant dehumidification system can greatly reduce the consumption of high-grade energy. To improve the advantages of liquid desiccant system compared with the conventional dehumidification system, one of the key measures is to increase...

متن کامل

Modeling and Simulation of the Heat Transfer Behaviour of a Shell-and-Tube Condenser for a Moderately High-Temperature Heat Pump

For many countries, increasing energy efficiency and reducing greenhouse gas emissions are key countermeasures to cope with the energy crisis and climate change. Of the various heating equipment such as heat pumps, gas-fired boilers, oil-fired boilers, or electric boilers, heat pumps are widely adopted for space heating, water heating, and process heating by households, business, and industry d...

متن کامل

Design, Installation, and Field Verification of Integrated Active Desiccant Hybrid Rooftop Systems Combined with a Natural Gas Driven Cogeneration Package

This report summarizes a research/demonstration project in which a new high school facility was designed and constructed to combine a custom built 230 kW cogeneration package with four integrated active desiccant rooftop (IADR) systems to serve as high-efficiency dedicated outdoor air systems (DOAS). The IADR systems were modified to include hot water coils to use the waste heat provided by the...

متن کامل

Regeneration performance of liquid desiccant on the surface of a plate-type heat exchanger

Recently, there have been many studies on dehumidifiers with a low flow rate of liquid desiccant, in which a plate-type heat exchanger with internal cooling is adopted. If the low flow rate of a liquid desiccant maintains a thin liquid film on the heat exchanger surface, heat and mass transfer performance would improve, the stability of the liquid film would increase, and there would be no entr...

متن کامل

Experimental study of nanofluid effects on heat transfer in closed cycle system in shell and tube heat exchangers at Isfahan power plant

The present study investigated the effect of distilled-water/ silver nanofluid on heat transfer in a closed cooling system of one of the electrical energy generation units at Isfahan power plant. The difference between this study and previous researches refers to silver properties which have a high thermal conductivity and is non-toxic, hydrophilic and eco-friendly. Distilled water/ silver ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017