Load Transfer Along the Bone-Implant Interface and Its Effects on Bone Maintenance
نویسندگان
چکیده
The long term success of dental implant treatment relies on the proper stability of the implant within the host bone. This condition is achieved through osseointegration, which is characterized as a direct functional and structural connection between ingrown bone tissue and implant surface (Brånemark et al., 1977; Simmons et al., 2001). Osseointegration begins with rapid growth of random and unorganized woven bone around the implant, while a biomechanically favorable environment at the bone-implant interface develops (Leucht et al., 2007; Schenk & Buser, 1998). This initial bony structure is maintained by bone remodeling and bone adaptation, where woven bone is slowly replaced by more organized lamellar bone. Adaptation of bone morphology in response to functional loads continues throughout life (Schenk & Buser, 1998). The load transfer from the implant to the host bone depends on the amount of bone surrounding the implant and in turn affects the success of treatment, by the load transfer from the implant to the host bone. X-ray imaging, computerized tomography (CT), and histomorphometric evaluation of the extracted implants provide insightful information about the quality and quantity of peri-implant bone. However, systematic evaluation of the mechanism of load transfer and its effect on peri-implant bone remodeling is difficult via aforementioned techniques, due to the cost and effort involved and due to the associated ethical concerns. Reliable computational models can be useful to predict the long term outcome of a dental implant treatment, and thus help with the decisions related to implant treatments and design. In this paper, a state of the art review of the computational models used in evaluating the biomechanics of dental implant systems is provided. The literature shows that load transfer along the bone-implant interface is not well understood, despite the fact that the bone loading starts along this interface. Recently a systematic investigation of the effects of various parameters related to a dental implant’s contour including the implant’s diameter, body-length, collar length and slope, and the morphology of the external threads was carried out by Faegh and Müftü (2010). The variation of normal and shear stresses along the bone dental-implant interface was investigated. Here, in order to generalize the bone morphology an elliptical contour is used. The results are compared to a similar recent study in which the bone contour was drawn from a CT image of the incisor region (Faegh & Müftü, 2010).
منابع مشابه
Load transfer along the bone-dental implant interface.
In this paper the variation of normal and shear stresses along a path defined on the bone-dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibula...
متن کاملThe axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.
This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...
متن کاملبررسی اثر ضخامت پوشش هیدروکسی آپاتیت بر توزیع تنش در اطراف سطح تماس ایمپلنت دندانی- استخوان با روش المان محدود
Background and Aims: Hydroxyapatite coating has allocated a special place in dentistry due to its biocompatibility and bioactivity. The purpose of this study was to evaluate the relation between the hydroxyapatite thickness and stress distribution by using finite element method. Materials and Methods: In this paper, the effect of hydroxyapatite coating thickness on dental implants was studi...
متن کاملNumerical study of effect of elastomeric stress absorbers on stress reduction in bone-dental implant interface
OBJECTIVE This paper focused on optimal stress distribution in the mandibular bone surrounding a dental implant and is devoted to the development of a modified Osteoplant® implant type in order to minimize stress concentration in the bone-implant interface. MATERIAL AND METHODS This study investigated 0.4 mm thick layers of two elastomeric stress barriers incorporated into the dental implant ...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کامل