چکیده

Reflections and patterns of dissipated power of 915 MHz water load produced by The Ferrite Company, Inc. are computed by QuickWave-3D for water temperatures from 5 to 60C. Simple model generalizing experimental data is used for calculating the dielectric constant of tap water. It is shown that low reflections take place for all operating temperatures, and microwave power is dissipated primarily within the conical part of water cavity, so possible shortening of its cylindrical part is suggested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement Infrastructure for Optimization and Characterization of Microwave Transistor Devices

various techniques and methods have evolved recently for the characterization and measurement of microwave devices. Waveform measurement and engineering system among them is a very promising candidate for the optimization and characterization of transistor device for use in power amplifier design. This paper presents an all encompassing waveform measurement and engineering system which is capab...

متن کامل

PEP-II B-Factory Prototype Higher Order Mode Load Design*

To reduce the impedance of the cavity higher order modes, (HOM’s), a compact broad-band, low-reflection, waveguide load is required with a VSWR less than 2:1 in the frequency range 714 MHz to 2500 MHz. The load must also work in the high vacuum of the cavity, and be capable of dissipating up to 10 kW of power which is generated by the the interaction of the beam with the cavity HOM’s and which ...

متن کامل

Two-Stage Stochastic Day-Ahead Market Clearing in Gas and Power Networks Integrated with Wind Energy

The significant penetration rate of wind turbines in power systems made some challenges in the operation of the systems such as large-scale power fluctuations induced by wind farms. Gas-fired plants with fast starting ability and high ramping can better handle natural uncertainties of wind power compared to other traditional plants. Therefore, the integration of electrical and natural gas syste...

متن کامل

Analysis of Operational Regimes of a High Power Water Load

Reflections, electric field and dissipated power of a 915 MHz water load produced by The Ferrite Company, Inc. are computed by QuickWave-3D for water temperatures from 5 to 60∞C. A simple empirical model generalizing experimental data is used for calculating the dielectric constant of fresh tap water at 915 MHz and for different temperatures. The computer model is verified by measurement of ref...

متن کامل

Nonlinear Analysis of a Power Amplifier inc C Band and Load Pull Technique Calculation USING VOLTERRA SERIES

In recent years, nonlinear circuit analysis techniques have been extensively investigated. One of the most important reasons is the application development of solid-state devices at microwave frequencies. Different methods have been used to analysis large signal behavior of these devices. In this paper load-pull curves (one of design requirement) are obtained using Volterra series. The main adv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002