A comparative study of identical VMAT plans with and without jaw tracking technique

نویسندگان

  • Hao Wu
  • Fan Jiang
  • Haizhen Yue
  • Qiaoqiao Hu
  • Jian Zhang
  • Zhuolun Liu
  • Jian Gong
  • Sha Li
  • Jianhao Geng
  • Yibao Zhang
چکیده

The unwanted radiation transmission through the multileaf collimators could be reduced by the jaw tracking technique which is commercially available on Varian TrueBeam accelerators. On the basis of identical plans, this study aims to investigate the dosimetric impact of jaw tracking on the volumetric-modulated arc therapy (VMAT) plans. Using Eclipse treatment planning system (TPS), 40 jaw-tracking VMAT plans with various tumor volumes and shapes were optimized. Fixed jaw plans were created by editing the jaw coordinates of the jaw-tracking plans while other parameters were identical. The deliverability of this artificial modification was verified using COMPASS system via three-dimentional gamma analysis between the measurement-based reconstruction and the TPS-calculated dose distribution. Dosimetric parameters of dose-volume histogram (DVH) were compared to assess the improvement of dose sparing for organs at risk (OARs) in jaw-tracking plans. COMPASS measurements demonstrated that over 96.9% of structure volumes achieved gamma values less than 1.00 at criteria of 3 mm/3%. The reduction magnitudes of maximum and mean dose to various OARs ranged between 0.06% ~ 6.76% (0.04 ~ 7.29 Gy) and 0.09% ~ 7.81% (0.02 ~ 2.78 Gy), respectively, using jaw tracking, agreeing with the disparities of radiological characteristics between MLC and jaws. Jaw tracking does not change the delivery efficiency and total monitor units. The dosimetric comparison of VMAT plans with and without jaw tracking confirms the physics hypotheses that reduced transmission through tracking jaws will reduce doses to OARs without sacrificing the target dose coverage because it is meant to be covered by radiation beams going through the opening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

PURPOSE To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. MATERIALS AND METHODS We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous inte...

متن کامل

Dosimetric Effect of Jaw Tracking in Volumetric-Modulated Arc Therapy

The aim of this study was to investigate the potential of jaw tracking with the volumetric-modulated arc therapy (VMAT) to reduce the normal tissue dose. Plans of nasopharynx, lung, and prostate cancers (10 plans for each) were used to perform VMAT with and without jaw tracking. The dose reduction was evaluated in terms of organ doses and integral doses. Organ-dose reduction with jaw tracking w...

متن کامل

Assessment of potential jaw‐tracking advantage using control point sequences of VMAT planning

This study aims to evaluate the potential jaw-tracking advantage using control point sequences of volume volumetric modulated arc therapy (VMAT) planning. VMAT plans for patients with prostate and head and neck (H&N) cancers were converted into new static arc (SA) plans. The SA plan consisted of a series of static fields at each control point of the VMAT plan. All other machine parameters o...

متن کامل

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.  Material...

متن کامل

Influence of the jaw tracking technique on the dose calculation accuracy of small field VMAT plans

PURPOSE The aim of this study was to evaluate experimentally the accuracy of the dose calculation algorithm AcurosXB in small field highly modulated Volumetric Modulated Arc Therapy (VMAT). METHOD The 1000SRS detector array inserted in the rotational Octavius 4D phantom (PTW) was used for 3D dose verification of VMAT treatments characterized by small to very small targets. Clinical treatment ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016