Carbon-felt-based bioelectrocatalytic flow-detectors: optimization of the adsorption conditions of horseradish peroxidase and thionine onto carbon-felt for highly sensitive amperometric determination of H2O2.

نویسندگان

  • Yue Wang
  • Yasushi Hasebe
چکیده

Horseradish peroxidase (HRP) and thionine (Th) were co-adsorbed onto a porous carbon-felt (CF) from a mixed solution of HRP and Th to fabricate a CF-based bioelectrocatalytic flow-detector for H(2)O(2). The resulting HRP and Th co-adsorbed CF (HRP/Th-CF) was successfully used as a working electrode unit of a highly sensitive amperometric flow-H(2)O(2)-biosensor. Differing from the ordinary mediator-based HRP biosensors, which detect mediated currents (i.e., the reduction current of the oxidized form of the mediators), the present HRP/Th-CF-based H(2)O(2)-biosensor directly detects the reduction current of the oxidative HRP-intermediates (i.e., compound I and II) based on a direct electron transfer (DET) between a HRP-redox active heme center and the CF electrode, because co-adsorbed Th together with HRP facilitate the DET. Various adsorption conditions (i.e., HRP concentration, Th concentration, ionic strength, pH, adsorption time) were optimized to obtain excellent sensor performances. When an air-saturated 0.1 M phosphate buffer (pH 7.0) was used as a carrier at 3.25 ml/min and the applied potential of - 0.05 V vs. Ag/AgCl, the HRP/Th-CF-based flow-H(2)O(2)-biosensor exhibited excellent analytical performances (i.e., sensitivity, 3.55 µA/µM; linear range, 0.1 to 10 µM; lower detection limit, 0.03 µM; K(m)(app), 36.2 µM; I(max), 158 µM; sample throughput, ca. 60 samples/h).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon-felt-based bioelectrocatalytic flow-detectors: role of ultrasound irradiation during the adsorption of horseradish peroxidase and thionine for a highly sensitive amperometric determination of H2O2.

This study reports on the first example, to our knowledge, of the usefulness of an ultrasound (US)-irradiation during an enzyme adsorption step, for enhancing the performance of a redox-enzyme-based amperometric biosensor. Horseradish peroxidase (HRP) and thionine (Th) were coadsorbed from a mixed aqueous solution of HRP and Th onto a carbon-felt (CF) under US-irradiation for 5 min with an ultr...

متن کامل

Carbon felt-based bioelectrocatalytic flow detectors: highly sensitive amperometric determination of hydrogen peroxide using adsorbed peroxidase and thionine.

Horseradish peroxidase (HRP) and thionine (TN) were co-adsorbed onto a porous carbon felt (CF), and the resulting HRP and TN-adsorbed CF (HRP-TN-CF) was successfully used as a working electrode unit of a novel bioelectrocatalytic flow detector for a highly sensitive amperometric determination of hydrogen peroxide (H(2)O(2)). Co-adsorbed TN was essential to enhance the cathodic peak current of H...

متن کامل

Carbon Felt-Based Bioelectrocatalytic Flow-Through Detectors: 2,6-Dichlorophenol Indophenol and Peroxidase Coadsorbed Carbon-Felt for Flow-Amperometric Determination of Hydrogen Peroxide

2,6-dichlorophenol indophenol (DCIP) and horseradish peroxidase (HRP) were coadsorbed on a porous carbon felt (CF) from their mixed aqueous solution under ultrasound irradiation for 5 min. The resulting DCIP and HRP-coadsorbed CF (DCIP/HRP-CF) showed an excellent bioelectrocatalytic activity for the reduction of H₂O₂. The coadsorption of DCIP together with HRP was essential to obtain larger bio...

متن کامل

Direct Electron Transfer-type Bioelectrocatalysis of Peroxidase at Mesoporous Carbon Electrodes and Its Application for Glucose Determination Based on Bienzyme System.

Non-catalytic direct electron transfer (DET) signal of Compound I of horseradish peroxidase (POD) was first detected at 0.7 V on POD/carbon nanotube mixture-modified electrodes. Excellent performance of DET-type bioelectrocatalysis was achieved with POD immobilized with glutaraldehyde on Ketjen Black (KB)-modified electrodes for H2O2 reduction with an onset potential of 0.65 V (vs. Ag | AgCl | ...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2011