Wall mechanics of the stented extracranial carotid artery.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Abrupt compliance changes and concomitant nonlaminar flow patterns may contribute to endothelial dysfunction and subsequent neointimal thickening. The aim of this study was to test the feasibility of wall mechanics measurement using B-mode ultrasound image analysis by dedicated software in the stented human carotid artery. METHODS Carotid Wallstents (Schneider) were placed in the extracranial carotid arteries of 15 patients. B-mode ultrasound examination was performed with a 7.5-MHz probe on the carotid artery upstream; at the proximal, mid, and distal stent levels; downstream from the stent; and on the contralateral internal and common carotid arteries. Carotid diameter (d) and systolic diameter changes (Deltad) were measured with a dedicated image processing system (IO version 3.1, IODP), while pulse blood pressure (DeltaP) was measured. Diameter compliance (Cd) and distensibility coefficient (DC) were calculated as Cd=2Deltad/DeltaP and DC=2Deltad/DeltaP/d and compared between measurement sites. RESULTS The evaluation could be completed in 8 of 15 patients. Compliance was significantly lower at the proximal, mid, and distal stent levels (27.77+/-1.11, 27.38+/-1.08, 27.38+/-1.09x10(-3) mm x kPa(-1)) than upstream (103.3+/-36.7x10(-3) mm x kPa(-1)), downstream (91.5+/-41.3x10(-3) mm x kPa(-1)), or on the contralateral internal (87.6+/-28x10(-3) mm x kPa(-1)) and common (149.3+/-47.6x10(-3) mm x kPa(-1)) carotid arteries. CONCLUSIONS Stenting of the extracranial carotid artery induces a compliance mismatch between the native and the stented artery.
منابع مشابه
Wall viscosity of the stented arteries.
Wall Viscosity of the Stented Arteries To the Editor: In the November 2003 issue of Stroke, Vernhet and colleagues reported a clinical analysis of wall mechanics in stented extracranial carotid arteries, and they concluded that stenting of these arteries induces a compliance mismatch between the native and the stented artery. Additionally, the authors observed a significant decrease in the dist...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملExtraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm
Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was...
متن کاملKinematics parameter extraction of longitudinal movement of common carotid arterial wall in healthy and atherosclerotic subjects based on consecutive ultrasonic image processing
Introduction:In this study, a non-invasive method based on consecutive ultrasonic image processing is introduced to assess time rate changes of the carotid artery wall displacement, velocity and acceleration in the longitudinal direction. The application of these parameters to discriminate healthy and atherosclerotic arteries was evaluated. Methods:Longitudinal displacement rate of common ...
متن کاملHemodynamic abnormalities in stented carotid artery – A fluid structure interaction study
Balloon-stented angioplasty is a common treatment for carotid arterial atherosclerosis. Clinical studies have shown that within 6 months of the initial procedure, 25% of all stented-angioplasty patients develop restenosis, a postoperative narrowing of the artery due to plaque accumulation onto the stent. While hemodynamics, and more specifically low oscillatory wall-shear stress have been ident...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 34 11 شماره
صفحات -
تاریخ انتشار 2003