Implant Stability - Measuring Devices and Randomized Clinical Trial for ISQ Value Change Pattern Measured from Two Different Directions by Magnetic RFA
نویسندگان
چکیده
Implant stability plays a critical role for successful osseointegration, which has been viewed as a direct structural and functional connection existing between bone and the surface of a load-carrying implant(Bränemark, et al. 1977, Sennerby & Roos 1998). Achievement and maintenance of implant stability are prerequisites for successful clinical outcome(Sennerby & Meredith 2008). Therefore, measuring the implant stability is an important method for evaluating the success of an implant. Implant stability is achieved at two different stages: primary and secondary. Primary stability of an implant comes from mechanical engagement with cortical bone. It is affected by the quantity and quality of bone that the implant is inserted into, surgical procedure, length, diameter, and form of the implant(Meredith 1998). Secondary stability is developed from regeneration and remodeling of the bone and tissue around the implant after insertion but is affected by the primary stability, bone formation and remodeling(Sennerby & Roos 1998). The time of functional loading is dependent upon the secondary stability. It is, therefore, of an utmost importance to be able to quantify implant stability at various time points and to project a long term prognosis based on the measured implant stability(Atsumi, et al. 2007).
منابع مشابه
Impact of mini-implant length on stability at the initial healing period: a controlled clinical study
INTRODUCTION Aim of the study was to assess the impact of the length of mini-implants inserted in the midpalatal region on the stability at the initial healing period. METHODS A sample of 20 consecutively treated patients (15.6 ± 7.2 years) was examined. A long mini-implant with a length of 11 mm and a diameter of 2 mm was inserted into the anterior palate of each patient. Resonance frequency...
متن کاملON STANDARD CALIBRATION OF ISQ TRANSDUCER PEGS. Prerequisites for accurate and comparable RFA measurements
The resonance frequency analysis (RFA) technique is widely used for stability assessments of dental implants. The technique makes use of a transducer peg, which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the peg. The underlying RF in Hz is then translated to an Implant Stability Quotient (ISQ) on a scal...
متن کاملUpdated secondary implant stability data of two dental implant systems. A retrospective cohort study
BACKGROUND At present, updated secondary implant stability data generated by actual versions of resonance frequency analysis (RFA) and mobility measurement (MM) electronic devices of 2 different implant systems with actual manufactured surfaces seem to lack and/or are incomplete. MATERIAL AND METHODS Secondary implant stability data based on both RFA and MM measurements were collected and ana...
متن کاملAssessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study
UNLABELLED Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. OBJECTIVE Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) ...
متن کاملA clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient
PURPOSE It has been suggested that primary implant stability plays an essential role in successful osseointegration. Resonance frequency analysis (RFA) is widely used to measure the initial stability of implants because it provides superior reproducibility and non-invasiveness. The purpose of this study is to investigate whether the fractal dimension from the panoramic radiograph is related to ...