Comparison of a Drug‐Free Early Programmed Dismantling PDLLA Bioresorbable Scaffold and a Metallic Stent in a Porcine Coronary Artery Model at 3‐Year Follow‐Up

نویسندگان

  • Kazuyuki Yahagi
  • Yi Yang
  • Sho Torii
  • Johanne Mensah
  • Roseann M. White
  • Marion Mathieu
  • Erica Pacheco
  • Masataka Nakano
  • Abdul Barakat
  • Tahmer Sharkawi
  • Michel Vert
  • Michael Joner
  • Aloke V. Finn
  • Renu Virmani
  • Antoine Lafont
چکیده

BACKGROUND Arterial Remodeling Technologies bioresorbable scaffold (ART-BRS), composed of l- and d-lactyl units without drug, has shown its safety in a porcine coronary model at 6 months. However, long-term performance remains unknown. The aim of this study was to evaluate the ART-BRS compared to a bare metal stent (BMS) in a healthy porcine coronary model for up to 3 years. METHODS AND RESULTS Eighty-two ART-BRS and 66 BMS were implanted in 64 Yucatan swine, and animals were euthanatized at intervals of 1, 3, 6, 9, 12, 18, 24, and 36 months to determine the vascular response using quantitative coronary angiography, optical coherence tomography, light and scanning electron microscopy, and molecular weight analysis. Lumen enlargement was observed in ART-BRS as early as 3 months, which progressively increased up to 18 months, whereas BMS showed no significant difference over time. Percentage area stenosis by optical coherence tomography was greater in ART-BRS than in BMS at 1 and 3 months, but this relationship reversed beyond 3 months. Inflammation peaked at 6 months and thereafter continued to decrease up to 36 months. Complete re-endothelialization was observed at 1 month following implantation in both ART-BRS and BMS. Scaffold dismantling started at 3 months, which allowed early vessel enlargement, and bioresorption was complete by 24 months. CONCLUSIONS ART-BRS has the unique quality of early programmed dismantling accompanied by vessel lumen enlargement with mild to moderate inflammation. The main distinguishing feature of the ART-BRS from other scaffolds made from poly-l-lactic acid may result in early and long-term vascular restoration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Head-to-head comparison of a drug-free early programmed dismantling polylactic acid bioresorbable scaffold and a metallic stent in the porcine coronary artery: six-month angiography and optical coherence tomographic follow-up study.

BACKGROUND We aimed to evaluate a new drug-free fully bioresorbable lactic acid-based scaffold designed to allow early dismantling synchronized with artery wall healing in comparison with a bare metal stent (BMS). METHODS AND RESULTS Twenty-three BMS (3.0×12 mm) and 36 lactic acid-based bioresorbable scaffolds (BRS, 3.0×11 mm) were implanted in porcine coronary arteries. QCA and optical coher...

متن کامل

Bioresorbable Scaffolds versus Metallic Stents in Routine PCI.

BACKGROUND Bioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice. METHODS We randomly assigned 1845 patie...

متن کامل

Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography

Fully bioresorbable vascular scaffolds (BVS; Abbott Vascular, Santa Clara, CA) offer a novel approach to the treatment of coronary artery disease by providing transient vessel support and drug delivery without the long-term limitations of durable metallic drug-eluting stents with durable polymers. After implantation, the poly-lactide struts of the BVS Background—The long-term fate of Absorb bio...

متن کامل

Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents

Second-generation metallic drug-eluting stents (DES) have been widely recommended for percutaneous coronary intervention. One of the main drawbacks of these devices is the risk of late adverse events (ie, beyond 1 year), particularly repeat revascularization, which are partly related to the persistence of the metallic stents in the coronary artery wall. In this context, the bioresorbable vascul...

متن کامل

1-year follow-up optical coherence tomography of a "hybrid" neocarina after T-stenting with small protrusion technique using a bioresorbable vascular scaffold and a metallic stent.

A 75-year-old man with stable angina underwent coronary angiography demonstrating significant stenosis at the bifurcation of the left anterior descending coronary artery (LAD) with a diagonal branch (Figure 1A). Following predilation, a 3.5 28-mm bioresorbable vascular scaffold (BVS) (Absorb, Abbott Vascular, Santa Clara, California) was implanted in the LAD. This was followed by post-dilation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017