Comparative assessment of clinical performance of esthetic bracket materials.

نویسندگان

  • Nikolaos Gkantidis
  • Spiros Zinelis
  • Marina Karamolegkou
  • Theodore Eliades
  • Nikolaos Topouzelis
چکیده

OBJECTIVES To compare the alterations in esthetic appearance and slot morphology/integrity of two main types of esthetic brackets caused after clinical use. MATERIALS AND METHODS Sixteen ceramic (CR) and 16 plastic (PR) central incisor brackets were obtained from 16 young adult patients at the end of treatment in a prospective randomized manner. As controls, 12 ceramic (CC) and 12 plastic (PC) nonused brackets were also examined. Three representative slot width measurements were obtained through micrometric microscopy. Visual inspection of optical microscopy images, surface electron microscopy (SEM), and energy-dispersive x-ray spectroscopy (EDS) were also performed. RESULTS Intraoral exposure time varied from 5 to 20 months (mean, 12.4; P  =  .73). Two-way analysis of variance revealed significant differences in slot width among the different materials and a significant interaction between the material effect and its status (P < .001). Bonferroni post hoc tests on material × status effect showed significant differences between CC (95% confidence interval [CI]: 434.5, 447.0) vs PC (95% CI: 460.2, 472.8), CC vs CR (95% CI: 453.2, 464.4), and PC vs PR (95% CI: 448.8, 458.9). Interestingly, a significant difference was not detected for CR vs PR. Slot width was correlated with the time under clinical use only for plastic brackets (PR: r  =  -.64, P < .01). Visual inspection of the optical microscopy images did not reveal any major macroscopic morphological disfigurements or significant discolorations. However, a rough and irregular slot wall surface was evident after clinical use (also with SEM), especially in the bottom of the slot. CONCLUSIONS Both bracket types presented adequate clinical performance at least for the time period studied and in terms of esthetic appearance and morphologic integrity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contemporary Esthetic Orthodontic Archwires – A Review

Growing demand of invisible braces byesthetically conscious patients has led to remarkable inventions in materials for esthetic labial archwires. Archwires with excellent optical clarity and mechanical properties comparable to conventional archwires have been manufactured by almost all the leading companies of orthodontic products in the past two decades, but their clinical use is still limited...

متن کامل

The Comparative Effect of Self-assessment vs. Peer-assessment on Young EFL Learners’ Performance on Selective and Productive Reading Tasks

This study aimed at investigating the comparative effect of using self-assessment vs. peer-assessment on young EFL learners’ performance on selective and productive reading tasks. To do so, 56 young learners from among 70 students in four intact classes were selected based on their performance on the A1 Movers Test. Then, the participants were randomly divided into two groups, self-assessment a...

متن کامل

Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study

STATEMENT OF THE PROBLEM Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. PURPOSE The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. MATERIALS AND METHOD The samples included 4 typ...

متن کامل

Influential Factor in Improving the Seismic Performance of the Kaiser Bolted Bracket Moment Connection

Following the Northridge earthquake of 1994, a significant number of steel moment resisting structural systems were damaged. Several studies have been conducted to improve the seismic performance of steel structures and specially their beam-to-column connections. One of the proposed connections for special moment-resisting frames included AISC-358 is Kaiser bolted bracket moment connection, bri...

متن کامل

Evaluation of mechanical properties of esthetic brackets

Plastic brackets, as well as ceramic brackets, are used in various cases since they have excellent esthetics. However, their mechanical properties remain uncertain. The purpose of this study was to determine how deformation and stress distribution in esthetic brackets differ among materials under the same wire load. Using the digital image correlation method, we discovered the following: (1) th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Angle orthodontist

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 2012