Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index.

نویسندگان

  • A L G Vanluchene
  • M M R F Struys
  • B E K Heyse
  • E P Mortier
چکیده

BACKGROUND We compared two spectral entropies, state entropy (SE) and response entropy (RE), based on the irregularity of the EEG, to measure loss of response to verbal command (LOR(verbal)) and noxious stimulus (LOR(noxious)) with the bispectral index (BIS) during propofol infusion with and without remifentanil. METHODS Three groups of 20 patients received an effect-site controlled propofol infusion (Ce(PROP)) starting at 1 microg ml(-1) and increased in steps of 0.5 microg ml(-1) at 4 min intervals. In addition, a remifentanil infusion was maintained at a group-dependent, fixed effect-site target concentration (Ce(REMI)) (0, 2 or 4 ng ml(-1)). The ability of BIS, SE or RE to predict LOR(verbal) and LOR(noxious) were compared with the changes in BIS, SE and RE using logistic regression, prediction probability (P(K)), and sensitivity/specificity. RESULTS In all groups, BIS, SE and RE decreased with increasing Ce(PROP). However, BIS decreased more smoothly than SE and RE at deeper levels of sedation. At LOR(verbal), BIS(50), SE(50) and RE(50) increased with increasing Ce(REMI). BIS, SE and RE all detected LOR(verbal) accurately but BIS performed better at 100% sensitivity. Sensitivity/specificity for detection of LOR(verbal) decreased for all methods with increasing Ce(REMI). LOR(noxious) was poorly described by all measures. CONCLUSION LOR(verbal) was detected accurately by BIS, SE and RE except for 100% sensitivity, where BIS performed better. Though BIS, SE and RE were influenced by remifentanil during propofol administration, their ability to detect LOR(verbal) remained accurate. None of the measures predicted LOR(noxious).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia.

BACKGROUND beta1-Adrenoceptor antagonists suppress the haemodynamic and arousal responses to tracheal intubation. The Entropy Module shows two spectral entropy-based indices, response entropy (RE) and state entropy (SE). The difference between RE and SE (RE-SE) may reflect nociception during general anaesthesia. In the present study, we investigated the effect of landiolol on entropy indices in...

متن کامل

Diagnosis of vertebral canal haematoma by myelography and spiral computer tomography in a patient with an implantable cardioverter-defibrillator contraindicating magnetic resonance imaging.

1 Aho AJ, Yli-Hankala A, Lyytikäinen L-P, Jäntti V. Facial muscle activity, Response Entropy, and State Entropy indices during noxious stimuli in propofol–nitrous oxide or propofol–nitrous oxide–remifentanil anaesthesia without neuromuscular block. Br J Anaesth 2009; 102: 227–33 2 Wheeler P, Hoffman WE, Baughman VL, Koenig H. Response entropy increases during painful stimulation. J Neurosurg An...

متن کامل

Monitoring of the responsiveness to noxious stimuli during anaesthesia with propofol and remifentanil by using RIII reflex threshold and bispectral index.

BACKGROUND Movement responses are an important indicator of noxious perception in the unconscious state. To allow for a continual monitoring of the responsiveness to noxious stimuli during general anaesthesia, surrogate parameters are needed. Here we compare the performance of the bispectral index (BIS) and the RIII threshold in predicting reactions to noxious stimuli during anaesthesia with pr...

متن کامل

Detection of awareness in surgical patients with EEG-based indices--bispectral index and patient state index.

BACKGROUND Patient state index (PSI) and bispectral index (BIS) are values derived from the EEG, which can measure the hypnotic component of anaesthesia. We measured the ability of PSI and BIS to distinguish consciousness from unconsciousness during induction and emergence from anaesthesia and a period of awareness in surgical patients. METHODS Forty unpremedicated patients were randomized to...

متن کامل

Comparison of spectral entropy and bispectral index electroencephalography in coronary artery bypass graft surgery.

OBJECTIVE The study's aim was to compare response entropy (RE) and state entropy (SE) with bispectral index (BIS) electroencephalography (EEG) as an alternative cerebral monitoring tool in patients scheduled for coronary artery bypass graft surgery. DESIGN Prospective, observational single-center study. SETTING University hospital. PARTICIPANTS Thirty patients undergoing coronary artery b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 93 5  شماره 

صفحات  -

تاریخ انتشار 2004