UNLABELLED The main objective of this work was the development of a skew-slit collimator for small-animal SPECT to replace the state-of-the-art multipinhole collimator. METHODS A pinhole forms a cone-beam imaging geometry. If the collimator rotates around the object in a circular orbit, the projection measurements acquired by the cone-beam imaging geometry are incomplete and not enough for artifact-free image reconstruction. The severity of the artifact is proportional to the cone angle of the pinhole in the direction of the axis of rotation. Multipinhole geometry can greatly reduce the data-insufficiency artifacts; however, image magnification is sacrificed. By transforming a pinhole into a pair of skewed slits, we are able to use a large cone angle in the transaxial direction to increase image magnification and a small cone angle in the direction of the axis of rotation to reduce data-insufficiency artifacts. This transformation is achieved by placing a vertical slit (i.e., the slit is parallel to the axis of rotation) close to the object and placing a horizontal slit farther out. Similar to the multipinhole collimator, we also propose a multiple-skew-slit collimator that has a single vertical slit and several horizontal slits. RESULTS Computer simulations were performed to verify the working principle of the skew-slit collimator. A prototype multiple-skew-slit collimator was fabricated, and phantom experiments were performed on a SPECT system. The smallest channels (of 0.75-mm diameter) in the phantom were clearly separated in the reconstructed image. CONCLUSION This study suggests a novel technology in small-animal SPECT to replace the multipinhole collimator, resulting in significantly reduced image artifacts and increased transaxial resolution. A physical multiple-skew-slit system was built and tested. Compared with the multipinhole system, the multiple-skew-slit system has a larger image magnification in the transaxial direction and thus has better image resolution.
منابع مشابه
An analytical algorithm for skew-slit imaging geometry with nonuniform attenuation correction.
The pinhole collimator is currently the collimator of choice in small animal single photon emission computed tomography (SPECT) imaging because it can provide high spatial resolution and reasonable sensitivity when the animal is placed very close to the pinhole. It is well known that if the collimator rotates around the object (e.g., a small animal) in a circular orbit to form a cone-beam imagi...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملCdZnTe strip detector SPECT imaging with a slit collimator.
In this paper, we propose a CdZnTe rotating and spinning gamma camera attached with a slit collimator. This imaging system acquires convergent planar integrals of a radioactive distribution. Two analytical image reconstruction algorithms are proposed. Preliminary phantom studies show that our small CdZnTe camera with a slit collimator outperforms a larger NaI(Tl) camera with a pinhole collimato...
متن کاملA study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography
Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...
متن کاملOptimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2008