RF Coil Technology for Small-Animal MRI

نویسندگان

  • F. David Doty
  • George Entzminger
  • Jatin Kulkarni
  • Kranti Pamarthy
  • John P. Staab
چکیده

A review of the theory, technology, and practice of RF coils for small-animal MRI is presented that includes a brief overview of MR S/N analysis and discussions of the various coils commonly used in small-animal MR – surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid-range coils – coils where the product (fd) of the frequency f and the coil diameter d is in the range of 2-30 MHz-m. Common applications include mouse brain and body coils from 125 MHz to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full-wave 3D EM software, and new simulation results are presented for a selection of surface coils using Microwave Studio (MWS) 2006 by Computer Simulation Technology (CST), showing the dramatic importance of the “lift-off effect”. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra-low-noise preamps based on the E-PHEMT (Enhancement mode Pseudomorphic High Electron Mobility Transistor) for optimal coil decoupling in phased arrays. Cryogenically cooled rf coils are shown to offer considerable opportunity for future gains in S/N in smaller samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

Characterization of Flexible RF Microcoil Dedicated to Surface Mri

In Magnetic Resonance Imaging (MRI), to achieve sufficient Signal to Noise Ratio (SNR), the electrical performance of the RF coil is critical. We developed a device (microcoil) based on the original concept of monolithic resonator. This paper presents the used fabrication process based on micromoulding. The dielectric substrates are flexible thin films of polymer, which allow the microcoil to b...

متن کامل

Actively Detunable 8-channel Small Animal Transceive Volume Array for 9.4T MRI systems

Introduction Ultra-high field MRI systems for small animals have seen a rapid development over recent years in a continuous effort to enhance SNR and spectral resolution of MRI images. To circumvent the associated high-field B1 inhomogeneity problem, methods such as RF shimming and Transmit SENSE have been proposed [1-2]. To benefit from the advantages of these techniques, dedicated phased-arra...

متن کامل

Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.

PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007