A simple model for examining issues in radiotherapy optimization.

نویسندگان

  • D M Shepard
  • G Olivera
  • L Angelos
  • O Sauer
  • P Reckwerdt
  • T R Mackie
چکیده

Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the field of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmetry. Because of the symmetry, the dose distribution for a pencil beam from any arbitrary angle can be determined through a simple rotation of a pre-computed dose matrix. Rapid dose calculations can thus be performed while maintaining the accuracy of a convolution/superposition based dose computation. The pencil beam data sets have been made publicly available. It is hoped that the data sets will facilitate a comparison of a variety of optimization and delivery approaches. This paper will present a number of studies designed to demonstrate the usefulness of the pencil beam data sets. These studies include an examination of the extent to which a treatment plan can be improved through either an increase in the number of beam angles and/or a decrease in the collimator size. A few insights into the significance of heterogeneity corrections for treatment planning for intensity modulated radiotherapy will also be presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TOPOLOGY OPTIMIZATION OF PERFORATED STEEL PLATE SHEAR WALLS WITH THICK PLATE IN SIMPLE FRAMES

In this paper, topology optimization (TO) is applied to determine the form, size and location of holes for the special form of perforated steel plate shear wall (PSPSW). The proposed model is based on the recently presented particular form of PSPSW that is called the ring-shaped steel plate shear wall. The strain energy is selected as the objective function in the optimization. Simple Isotropic...

متن کامل

Developement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...

متن کامل

Optimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm

Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...

متن کامل

Radiotherapy techniques for intracranial tumours

ABSTRACTIntracranial tumours often require radiotherapeutic approaches that differ from other sites. Their specific requirements merit a specialized discussion. A brief review of radiotherapy techniques to treat intracranial tumours is presented with emphasis on the author’s own experience and work, where appropriate. A clinical introduction is presented first followed by a description of bot...

متن کامل

A multi-objective genetic algorithm for a mixed-model assembly U-line balancing type-I problem considering human-related issues, training, and learning

Mixed-model assembly lines are increasingly accepted in many industrial environments to meet the growing trend of greater product variability, diversification of customer demands, and shorter life cycles. In this research, a new mathematical model is presented considering balancing a mixed-model U-line and human-related issues, simultaneously. The objective function consists of two separate com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 26 7  شماره 

صفحات  -

تاریخ انتشار 1999