Upgradation of Power flow in EHV AC transmission

نویسنده

  • K.K.Vasishta Kumar
چکیده

Transient stability plays key role for the loading of Extra High Voltage AC lines under their thermal limits. It is not possible to load these EHV lines near the thermal limits. But, with the proposed scheme in this paper, it is possible to load these lines very close to their thermal limits. Master current controller senses ac current and regulates the dc current orders for converters online such that conductor current never exceeds its thermal limit. In this scheme, the ac line conductors are superimposed with dc power flow and it doesn’t cause any transient instability. This paper presents the converting of an ac line into composite ac-dc power transmission line to improve transient stability and damping out the oscillations. With Matlab/Simulink software the thermal limits are satisfactory and the gain in the load ability of the line is obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power System Stability Enhancement by Simultaneous AC-DC Power Transmission

This paper presents the concept of simultaneous ac-dc power transmission. Long extra high voltage (EHV) ac lines cannot be loaded to their thermal limits due to this instability occurs in the power system. It is difficult to load long extra high voltage (EHV) ac lines to their thermal limits as a sufficient margin is kept against transient instability. With the model proposed in this thesis, it...

متن کامل

Enhanced Loadability of Existing Ehvac Line by Combined Ac-dc Transmission System

Now-a-days, demand for electric power has shown steady but geographically uneven growth.The wheeling of the available energy through existing long ac lines to load centers has a certain upper limit due to stability considerations. Thermal limit is the major limit to be considered while increasing loadability of existing EHV long transmission lines. Thus, these lines cannot be loaded to their th...

متن کامل

Power Upgrading of Transmission Line by Combining AC–DC Transmission

Long extra high voltage (EHV) ac lines cannot be loaded to their thermal limits in order to keep sufficient margin against transient instability. With the scheme proposed in this project, it is possible to load these lines very close to their thermal limits. The conductors are allowed to carry usual ac along with dc superimposed on it. The added dc power flow does not cause any transient instab...

متن کامل

Effect of Distributed Power-Flow Controller (DPFC) on Power System Stability

Distributed flexible AC- transmission system (D-FACTS) is a recently advanced FACTS device with high flexibility and smaller size. The DPFC can control power flow in transmission lines, regulate bus voltages and it can also enhance stability margin in power grids. Adaptive-neural network-based fuzzy inference system (ANFIS) combines features of artificial neural network and fuzzy controller. Th...

متن کامل

Simultaneous Control of Active and Reactive Powers of Vanadium Redox Flow Battery Systems in Flexible Microgrids

This paper discusses the control of flexible microgrids, consisting of a Redox Flow Batteries (RFB) and a new power conditioning system (PCS) for the RFB. Considering the importance of energy storage, this study is essential in power systems that are developed cautiously. RFB is connected to power system by a DC/DC or DC/AC converter to produce a DC voltage. It is very important that this conve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012