Operational radiation protection in high-energy physics accelerators: implementation of ALARA in design and operation of accelerators.
نویسندگان
چکیده
This paper considers the historical evolution of the concept of optimisation of radiation exposures, as commonly expressed by the acronym ALARA, and discusses its application to various aspects of radiation protection at high-energy accelerators.
منابع مشابه
Assessment of polymer composite reinforced with nanomaterial against ionizing radiation
Introduction: Unwanted exposure of ionizing radiation may result in carcinogenesis, cell mutations, and organ failure. High-atomic number elements such as lead, tungsten, bismuth have been traditionally used for radiation protection. Theoretical and practical studies have shown that a variety of shielding materials e.g. polymer composites (PCs) can be used for attenuation of th...
متن کاملA Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear accelerator
Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...
متن کاملA Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear accelerator
Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...
متن کاملUnexpected dose and the biological effect of neutron contamination in linear accelerators
Employing High-energy photons in medical linear accelerators can lead to neutron contamination. The relative biological effect of neutrons is 20 times higher than photons. Consequently, its damage to the biological tissue is much higher and unobtrusive. In this study, we calculated neutron equivalent dose in a medical linear accelerator by the FLUKA Monte Carlo code system. The results show tha...
متن کاملNew Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators
Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 137 1-2 شماره
صفحات -
تاریخ انتشار 2009