Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT.
نویسندگان
چکیده
BACKGROUND Coronary artery calcium (CAC) predicts coronary heart disease events and is important for individualized cardiac risk assessment. This report assesses the interscan variability of CT for coronary calcium quantification using image acquisition with standard and reduced radiation dose protocols and whether the use of reduced radiation dose acquisition with iterative reconstruction (IR; "reduced-dose/IR ") allows for similar image quality and reproducibility when compared to standard radiation dose acquisition with filtered back projection (FBP; "standard-dose/FBP") on 320-detector row computed tomography (320-CT). METHODS 200 consecutive patients (60 ± 9 years, 59% male) prospectively underwent two standard- and two reduced-dose acquisitions (800 total scans, 1600 reconstructions) using 320 slice CT and 120 kV tube voltage. Automated tube current modulation was used and for reduced-dose scans, prescribed tube current was lowered by 70%. Image noise and Agatston scores were determined and compared. RESULTS Regarding stratification by Agatston score categories (0, 1-10, 11-100, 101-400, >400), reduced-dose/IR versus standard-dose/FBP had excellent agreement at 89% (95% CI: 86-92%) with kappa 0.86 (95% CI: 0.81-0.90). Standard-dose/FBP rescan agreement was 93% (95% CI: 89-96%) with kappa = 0.91 (95% CI: 0.86-0.95) while reduced-dose/IR rescan agreement was similar at 91% (95% CI: 87-94%) with kappa 0.88 (95% CI: 0.83-0.93). Image noise was significantly higher but clinically acceptable for reduced-dose/IR (18 Hounsfield Unit [HU] mean) compared to standard-dose/FBP (16 HU; p < 0.0001). Median radiation exposure was 74% lower for reduced- (0.37 mSv) versus standard-dose (1.4 mSv) acquisitions. CONCLUSION Rescan agreement was excellent for reduced-dose image acquisition with iterative reconstruction and standard-dose acquisition with filtered back projection for the quantification of coronary calcium by CT. These methods make it possible to reduce radiation exposure by 74%. CLINICAL TRIAL REGISTRATION URL: https://clinicaltrials.gov/ct2/show/NCT01621594. UNIQUE IDENTIFIER NCT01621594.
منابع مشابه
Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience
Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new...
متن کاملLow kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose
Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...
متن کاملRadiation exposure for coronary artery calcium score at prospective 320 row multi - detector computed tomography
Purpose: To date there is extensive data on the radiation dose for assessing coronary artery calcium scores (CACS) with 4-64 row multidetector MDCT. However with the advent of 320 row MDCT, the entire heart can be imaged in one beat and thus potentially reduce the radiation dose. The aim of this study was to evaluate radiation dose for CACS on low-dose prospective EKG-triggered 320 row MDCT. Ma...
متن کاملInfluence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
The objective of this study was to investigate the impact of image acquisition settings and patients' characteristics on image quality and radiation dose for coronary angiography by 320-row computed tomography (CT). CORE320 is a prospective study to investigate the diagnostic performance of 320-detector CT for detecting coronary artery disease and associated myocardial ischemia. A run-in phase ...
متن کاملImpact of iterative reconstruction vs. filtered back projection on image quality in 320-slice CT coronary angiography
Iterative reconstruction has been shown to reduce image noise compared with traditional filtered back projection with quantum denoising software (FBP/QDS+) in CT imaging but few comparisons have been made in the same patients without the influence of interindividual factors. The objective of this study was to investigate the impact of adaptive iterative dose reduction in 3-dimensional (AIDR 3D)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular computed tomography
دوره 10 5 شماره
صفحات -
تاریخ انتشار 2016