Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients.

نویسندگان

  • Desmond T B Yeo
  • Thomas L Chenevert
  • Jeffrey A Fessler
  • Boklye Kim
چکیده

A simple phase error correction technique used for field map estimation with a generally available dual-echo gradient-echo (GRE) sequence is presented. Magnetic field inhomogeneity maps estimated using two separate GRE volume acquisitions at different echo times are prone to dynamic motion errors between acquisitions. By using the dual-echo sequence, the data are collected during two back-to-back readout gradients in opposite polarity after a single radio frequency pulse, and interecho motion artifacts and alignment errors in field map estimation can be factored out. Residual phase error from the asymmetric readout pulses is modeled as an affine term in the readout direction. Results from phantom and human data suggest that the first-order phase correction term stays constant over time and, hence, can be applied to different data acquired with the same protocol over time. The zero-order phase correction term may change with time and is estimated empirically for different scans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Robust Field-map Estimation Method Using Dual-echo GRE with Bipolar Readout Gradient Structure

D. Yeo, T. L. Chenevert, J. A. Fessler, B. Kim Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States, Radiology, University of Michigan Medical School, Ann Arbor, MI, United States Introduction: Field-maps are typically required to correct for field-inhomogeneity artifacts like geometric distortion in EPI and blurring in spiral acquisitions [1,2]. Wit...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

Analysis of Streak Artifacts in Gradient-Echo EPI Sequence Using 1.5T MRI System

Introduction Even though echo-planar-imaging (EPI) sequence is the fastest imaging method, EPI sequences (gradient-echo (GRE) or spin-echo (SE)) have limitations in application areas due to two major artifacts, Nyquist ghost artifact and geometric distortion. In order to reduce the ghost and geometric artifacts, nonlinear phase correction methods were developed [1]. However, the nonlinear phase...

متن کامل

Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

OBJECTIVES The goal of this work was to reduce the scan time of contrast-enhanced whole-heart coronary magnetic resonance angiography (MRA) by using a gradient echo interleaved echo planar imaging (GRE-EPI) sequence at 3 T field strength. MATERIALS AND METHODS A GRE-EPI sequence was optimized to acquire contrast-enhanced whole-heart coronary MRA at 3 T. First-order phase correction was used f...

متن کامل

Autocalibrating Correction of Spatially Variant Eddy Currents for Three-Point Dixon Imaging

Introduction Three-point Dixon methods assume in the separation linearity between the common phase of water and fat and the echo time [1]. The contributions to the common phase from field inhomogeneity adhere to linearity. In acquisitions that employ bipolar readout gradients to increase scan efficiency and decrease echo spacing, however, the common phase also includes contributions from eddy c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 2007