The impact of combined cardiopulmonary exercise testing and SPECT myocardial perfusion imaging on downstream evaluation and management.

نویسندگان

  • Georgios Christopoulos
  • John Bois
  • Thomas G Allison
  • Martin Rodriguez-Porcel
  • Panithaya Chareonthaitawee
چکیده

OBJECTIVE The diagnostic yield of combined cardiopulmonary exercise testing (CPET) and myocardial perfusion imaging (MPI) in patients referred for stress testing has received limited study. METHODS We evaluated consecutive patients who underwent combined CPET-MPI at a single tertiary referral center between 2011 and 2015. An abnormal CPET was defined as any of the following: reduced oxygen consumption, cardiac output impairment, or pulmonary impairment. Normal MPI was defined as the absence of resting or stress perfusion defect. The primary study outcome was change in clinical decision-making after CPET-MPI including management of pulmonary disease, management of deconditioning, heart failure management, and referral for cardiac catheterization. Outcomes of patients with normal and abnormal MPI were presented based on the specific CPET abnormality. RESULTS 415 patients were included in the study. Of the 269 patients that had normal MPI, 206 (77%) had abnormal CPET. Patients with abnormal CPET and normal MPI, compared with patients that had normal CPET and normal MPI, were more frequently diagnosed with pulmonary disease (11.7% vs 3.2%, P = .04) and deconditioning (33.5% vs 17.4%, P = .01). Of the 146 patients that had abnormal MPI, 128 (88%) had abnormal CPET. Patients with abnormal CPET and abnormal MPI, compared with patients that had normal CPET and abnormal MPI, did not statistically differ with regard to the study outcome. CONCLUSION An abnormal CPET, if the MPI was normal, prompted further evaluation and led to management of pulmonary disease and deconditioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benefits of combined pharmacologic and submaximal exercise stress on Sub-diaphragmatic activity in myocardial perfusion scintigraphy

Introduction: Myocardial perfusion imaging (MPI) is an important imaging modality in managing patients with cardiovascular disease. MPI has a significant role in diagnosis and management of cardiovascular disease; however it is subjected to different artifacts. Combining pharmacologic stress with submaximal exercise reduces side effects, improves image quality, and enhances the...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease

Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

High negative predictive value of workload ≥7 METS on exercise testing in patients with normal gated myocardial perfusion imaging: Was imaging really required?

Introduction: Good functional capacity has a high negative predictive value (NPV) in patients with known or suspected coronary artery disease (CAD) similar to a normal gated myocardial perfusion imaging (GMPI). Aim of this study was to evaluate NPV of functional capacity during treadmill exercise in patients with normal GMPI in Pakistani population. Methods: This was a prospective study which ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology

دوره   شماره 

صفحات  -

تاریخ انتشار 2017