Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography
نویسندگان
چکیده
To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients who underwent CCTA were prospectively randomized into two groups. Group A (n = 80) used individualized-protocol with adjusted injection rate based on patient weight and contrast medium concentration to obtain constant iodine load of 280 mgI/kg while group B (n = 80) followed the conventional contrast injection protocol with total injection volume of 80ml and constant injection rate of 5.5ml/s. For both groups, patients were further divided into four subgroups with different CM concentrations: A1, B1 (300 mg I/ml); A2, B2 (320 mg I/ml); A3, B3 (350 mg I/ml) and A4 and B4 (370 mg I/ml). For each patient, the CT values of the ascending aorta, left ventricle and coronary arteries were measured. One-way analysis of variance was used to compare CT values among subgroups. Among the subgroups of A, sufficient attenuation of greater than 300HU was obtained in all target vessels with no difference among them. Among the subgroups of B, the CT values had significant difference in left ventricle, left circumflex branch, proximal and distal segment of the right coronary artery (all p < 0.05), and the attenuation with 300 mg I/ml CM concentration was significantly lower than that with 370 mg I/ml. Compared with group B, group A used less volume (62.83 ml vs. 80.00 ml, P<0.001) and lower rate (5.21 ml/s vs. 5.50 ml/s, P<0.001) of CM. Compared with the conventional contrast medium injection protocol with fixed volume and injection rate, the individualized-protocol based on patient weight and contrast concentration provides overall contrast dose reduction and achieves more homogenous attenuation among different coronary vessels and patients.
منابع مشابه
Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملAn assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System
Introduction: In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray examinations and it contributes 34% of the resultant collective dose worldwide. Children are more sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be carried out periodically on the CT scanners. The aim of this research was to estimate the effective ...
متن کاملThe effect of CT contrast agents on treatment planning and dose calculation in radiation therapy of pelvis cancers
Introduction: Using contrast medium in diagnosis and identifying of an organ from its surrounding tissue is very useful. These contrast mediums alter radiation absorption of studied organs. The aim of this study is to identify the influences of contrast media in treatment planning system of the pelvis. Materials and Methods: Seven patients with pelvis area ...
متن کاملContrast Enhancement of the Right Ventricle during Coronary CT Angiography – Is It Necessary?
PURPOSE It is unclear if prolonged contrast media injection, to improve right ventricular visualization during coronary CT angiography, leads to increased detection of right ventricle pathology. The purpose of this study was to evaluate right ventricle enhancement and subsequent detection of right ventricle disease during coronary CT angiography. MATERIALS AND METHODS 472 consecutive patients...
متن کاملEffect of concentration of contrast medium on coronary CT angiography.
OBJECTIVE To compare concentration of contrast medium for vascular opacification at ascending aorta using retrospective reconstruction of coronary CT angiography. STUDY DESIGN Retrospective study. MATERIAL AND METHOD Eighty-four patients undergoing coronary CT angiography with 16 multi-detector rows at Siriraj Hospital between September 2003 and July 2004 were included in this study. The pa...
متن کامل