Synchronous imaging of coherent plasma fluctuations.

نویسندگان

  • S R Haskey
  • N Thapar
  • B D Blackwell
  • J Howard
چکیده

A new method for imaging high frequency plasma fluctuations is described. A phase locked loop and field programmable gate array are used to generate gating triggers for an intensified CCD camera. A reference signal from another diagnostic such as a magnetic probe ensures that the triggers are synchronous with the fluctuation being imaged. The synchronous imaging technique allows effective frame rates exceeding millions per second, good signal to noise through the accumulation of multiple exposures per frame, and produces high resolution images without generating excessive quantities of data. The technique can be used to image modes in the MHz range opening up the possibility of spectrally filtered high resolution imaging of MHD instabilities that produce sufficient light fluctuations. Some examples of projection images of plasma fluctuations on the H-1NF heliac obtained using this approach are presented here.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online Aggregation of Coherent Generators Based on Electrical Parameters of Synchronous Generators

This paper proposes a novel approach for coherent generators online clustering in a large power system following a wide area disturbance. An interconnected power system may become unstable due to severe contingency when it is operated close to the stability boundaries. Hence, the bulk power system controlled islanding is the last resort to prevent catastrophic cascading outages and wide area bl...

متن کامل

Label-free classification of cell types by imaging of cell membrane fluctuations using low-coherent full-field quantitative phase microscopy

Cell membrane motions of living cells are quantitatively measured in nanometer resolution by low-coherent full-field quantitative phase microscopy. Our setup is based on a full-field phase shifting interference microscope with a very lowcoherent light source. The reflection mode configuration and the low-coherent illumination make it possible to differentiate the weak reflection light from the ...

متن کامل

Induced spermiation of rainbow trout, Oncorhynchus mykiss, using a GnRh analogue

In this study, the benefits of using the first Iranian made GnRHa[D-Ala6 des Gly10] mGnRH ethylamide, to induce spermiation in male rainbow trout, Oncorhynchus mykiss, were evaluated, In addition, its effect on acceleration and synchronization, quality and quantity of milt and the plasma Testosterone (T) fluctuations were examined. For these purposes, 40 non-spermiating male rainbow trouts were...

متن کامل

Imaging coherent transport in graphene. Part I: mapping universal conductance fluctuations.

Graphene provides a fascinating testbed for new physics and exciting opportunities for future applications based on quantum phenomena. To understand the coherent flow of electrons through a graphene device, we employ a nanoscale probe that can access the relevant length scales--the tip of a liquid-He-cooled scanning probe microscope (SPM) capacitively couples to the graphene device below, creat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 85 3  شماره 

صفحات  -

تاریخ انتشار 2014