Compartment Syndrome of the Thigh Following Manipulation to Treat Knee Stiffness after Total Knee Arthroplasty

نویسندگان

  • Ju Hong Lee
  • Seong-Il Wang
چکیده

A 67-year-old man developed compartment syndrome of the thigh following manipulation for treatment of knee stiffness after a total knee arthroplasty. Three months earlier, he had undergone arthroscopic synovectomies twice for treatment of septic arthritis in the same leg. Manipulation for treatment of stiffness concomitant with periarticular inflammation is a possible risk factor of compartment syndrome.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute compartment syndrome of the thigh after joint replacement with anticoagulation.

We describe three patients with a compartment syndrome of the thigh, two after total hip replacement and one after total knee replacement. Two of the patients were fully anticoagulated. A compartment syndrome of the thigh is a rare, but important complication of joint replacement surgery if patients are receiving anticoagulants. Close observation is needed and when indicated monitoring of the i...

متن کامل

Migration of a Broken Steinman Pin into the Posterior Compartment of the Leg 12 Years after Total Hip Arthroplasty

This report is on a migration of a Steinman pin into the posterior com Department of the calf. It was used to fix a greater trochanteric osteotomy in a total hip arthroplasty. The puzzling note is how this metal piece passed through the anterolateral compartment of the thigh to the posterior compartment of the calf. Accord ing to our literature review, migration of fixation pins through the kne...

متن کامل

Regional Anesthesia Did Not Delay Diagnosis of Compartment Syndrome: A Case Report of Anterior Compartment Syndrome in the Thigh Not Masked by an Adductor Canal Catheter

BACKGROUND Acute compartment syndrome (ACS) of the thigh after elective primary total knee arthroplasty is rare. If not recognized and treated promptly, devastating consequences may result. Certain regional anesthesia techniques are thought to mask the symptoms of acute compartment syndrome, but there are no cases reported of adductor canal catheters masking the symptoms of thigh compartment sy...

متن کامل

Treating Stiffness After Total Knee Arthroplasty: A Technical Note and Preliminary Results

Total Knee Replacement is used to treat pain, stiffness and reduced range of movement. It has been estimated that a minimum of 90 degrees of range of motion in the knee is required for normal activities of daily living. In this article we demonstrate a technical note with a small patient series about the methods of treating knee stiffness after Total Knee Replacement.

متن کامل

Low manipulation prevalence following fast-track total knee arthroplasty

BACKGROUND AND PURPOSE Postoperative joint stiffness following total knee arthroplasty (TKA) may compromise the outcome and necessitate manipulation. Previous studies have not been in a fast-track setting with optimized pain treatment, early mobilization, and short length of stay (LOS), which may have influenced the prevalence of joint stiffness and subsequent manipulation. We investigated the ...