Estimation of the bispectral index by anesthesiologists: an inverse turing test.

نویسندگان

  • Michael M Bottros
  • Ben Julian A Palanca
  • George A Mashour
  • Ami Patel
  • Catherine Butler
  • Amanda Taylor
  • Nan Lin
  • Michael S Avidan
چکیده

BACKGROUND Processed electroencephalographic indices, such as the bispectral index (BIS), are potential adjuncts for assessing anesthetic depth. While BIS® monitors might aid anesthetic management, unprocessed or nonproprietary electroencephalographic data may be a rich source of information for clinicians. We hypothesized that anesthesiologists, after training in electroencephalography interpretation, could estimate the index of a reference BIS as accurately as a second BIS® monitor (twin BIS®) (Covidien Medical, Boulder, CO) when provided with clinical and electroencephalographic data. METHODS Two sets of electrodes connected to two separate BIS® monitors were placed on the foreheads of 10 surgical patients undergoing general anesthesia. Electroencephalographic parameters, vital signs, and end-tidal anesthetic gas concentrations were recorded at prespecified time points, and were provided to two sets of anesthesiologists. Ten anesthesiologists received brief structured training in electroencephalograph interpretation and 10 were untrained. Although electroencephalographic waveforms and open-source processed electroencephalograph metrics were provided from the reference BIS®, both groups were blinded to BIS values and were asked to estimate BIS. RESULTS The trained anesthesiologists averaged as close to or closer to the reference BIS® compared with the twin BIS® monitor for 34% of their BIS estimates versus 26% for the untrained anesthesiologists. Using linear mixed effects model analysis, there was a statistically significant difference between the trained and untrained anesthesiologists (P = 0.02), but no difference between the twin BIS® monitor and trained anesthesiologists (P = 0.9). CONCLUSION With limited electroencephalography training and access to clinical data, anesthesiologists can estimate the BIS almost as well as a second BIS® monitor. These results reinforce the potential utility of training anesthesia practitioners in unprocessed electroencephalogram interpretation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Anesthesia Depth Using Effective Brain Connectivity Based on Transfer Entropy on EEG Signal

Introduction: Ensuring an adequate Depth of Anesthesia (DOA) during surgery is essential for anesthesiologists. Since the effect of anesthetic drugs is on the central nervous system, brain signals such as Electroencephalogram (EEG) can be used for DOA estimation. Anesthesia can interfere among brain regions, so the relationship among different areas can be a key factor in the anesthetic process...

متن کامل

بررسی مقایسه‌ای انفوزیون مداوم رمی‌فنتانیل و پاراستامول بر میزان عمق بیهوشی با مونیتورینگ BIS در اعمال جراحی اندوسکوپی سینوس

    Background & Aim: Paracetamol is a non-opioid and non-NSAID(non non-steroidal anti-inflammatory drug) analgesic with central function. Analgesic effect of paracetamol is similar to opioids and NSAIDs but different from them in terms of side effects. Remifentanil is a short-acting opioid. In our study, we assess the effect of these two drugs on the depth of anesthesia using BIS monitoring. B...

متن کامل

Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

متن کامل

Assessment of depth of anesthesia: PRST score versus bispectral index.

UNLABELLED Assessment of depth of anesthesia is the basis in anesthesiologists work because the occurrence of awareness during general anesthesia is important due to stress, which is caused in the patient at that moment, and due to complications that may arise later. There are subjective and objective methods used to estimate the depth of anesthesia. The aim of this study was to assess the dept...

متن کامل

تاثیر سن بالا بر روی شاخص دو طیفی (Bispectral Index) قبل و بعد از تزریق آرام‌بخش: یک مطالعه آینده‌نگر

Background: The Bispectral Index (BIS) is an EEG-derived value that measures the sedative and hypnotic component of the anesthetic state. The effects of age on the bispectral index have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and bispectral index in awake and in patients with sedation induced by midazolam.Methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 114 5  شماره 

صفحات  -

تاریخ انتشار 2011