Photoacoustic correlation spectroscopy and its application to low-speed flow measurement.
نویسندگان
چکیده
A photoacoustic correlation technique, inspired by its optical counterpart-the fluorescence correlation spectroscopy (FCS)-was tested for the first time, to our knowledge, to demonstrate the feasibility of low-speed flow measurement based on photoacoustic signal detection. A pulsed laser was used to probe the flow of light-absorbing beads. A photoacoustic correlation system of 0.8 s temporal resolution was built and flow speeds ranging from 249 to 14.9 microm/s with corresponding flow times from 4.42 to 74.1 s were measured. The experiment serves as a proof of concept for photoacoustic correlation spectroscopy, which may have many potential applications similar to the FCS.
منابع مشابه
In vivo flow speed measurement of capillaries by photoacoustic correlation spectroscopy.
We recently proposed photoacoustic correlation spectroscopy (PACS) and demonstrated a proof-of-concept experiment. Here we use the technique for in vivo flow speed measurement in capillaries in a chick embryo model. The photoacoustic microscopy system is used to render high spatial resolution and high sensitivity, enabling sufficient signals from single red blood cells. The probe beam size is c...
متن کاملFast photoacoustic-guided depth-resolved Raman spectroscopy: a feasibility study.
In this Letter, photoacoustic-guided Raman spectroscopy (PARS) is proposed for a fast depth-resolved Raman measurement with accurate depth localization. The approach was experimentally demonstrated to receive both photoacoustic and Raman signals from a three-layer agar phantom based on a developed synergic photoacoustic-Raman probe, showing strong depth correlation and achieving magnitude of fa...
متن کاملIn vivo optically encoded photoacoustic flowgraphy.
We present an optically encoded photoacoustic (PA) flow imaging method based on optical-resolution PA microscopy. An intensity-modulated continuous-wave laser photothermally encodes the flowing medium, and a pulsed laser generates PA waves to image the encoded heat pattern. Flow speeds can be calculated by cross correlation. The method was validated in phantoms at flow speeds ranging from 0.23 ...
متن کاملCross-correlation-based transverse flow measurements using optical resolution photoacoustic microscopy with a digital micromirror device.
A cross-correlation-based method is proposed to quantitatively measure transverse flow velocity using optical resolution photoacoustic (PA) microscopy enhanced with a digital micromirror device (DMD). The DMD is used to alternately deliver two spatially separated laser beams to the target. Through cross-correlation between the slow-time PA profiles measured from the two beams, the speed and dir...
متن کاملHigh-frequency photoacoustic imaging of erythrocyte aggregation and oxygen saturation: probing hemodynamic relations under pulsatile blood flow
In this paper, we investigate the feasibility of high-frequency photoacoustic (PA) imaging to study the shear rate dependent relationship between red blood cell (RBC) aggregation and oxygen saturation (SO2) in a simulated blood flow system. The PA signal amplitude increased during the formation of aggregates and cyclically varied at intervals corresponding to the beat rate (30, 60, 120, 180 and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 35 8 شماره
صفحات -
تاریخ انتشار 2010