Investigation of the isoplanatic patch and wavefront aberration along the pupillary axis compared to the line of sight in the eye
نویسندگان
چکیده
Conventional optical systems usually provide best image quality on axis, while showing unavoidable gradual decrease in image quality towards the periphery of the field. The optical system of the human eye is not an exception. Within a limiting boundary the image quality can be considered invariant with field angle, and this region is known as the isoplanatic patch. We investigate the isoplanatic patch of eight healthy eyes and measure the wavefront aberration along the pupillary axis compared to the line of sight. The results are used to discuss methods of ocular aberration correction in wide-field retinal imaging with particular application to multi-conjugate adaptive optics systems.
منابع مشابه
Effects of Flight Dynamics on Performance of One Axis Gimbal System, Considering Disturbance Torques
The gimbal stabilization mechanism system is used to provide the stability to an object mounted on the gimbal by isolating it from the base angular motion and vibration. In this paper the model of one axis gimbal system with dynamics flying object is introduced. The gimbal torque relationships are obtained using Newton’s second law equation on the assumption that gimbal is rigid body. The syste...
متن کاملModeling, Control and Simulation of Cascade Control Servo System for one Axis Gimbal Mechanism
The gimbal stabilization mechanism is used to provide the stability to an object mounted on the gimbal by isolating it from the base angular motion and vibration. The purpose of this paper is to present a model of control servo system for one axis gimbal mechanism using a cascade PID controller. The gimbal torque relationships are derived by taking into consideration the base angular motion. Th...
متن کاملEvaluation of Visual Signs and Symptoms in Patients with Alzheimer's Disease
Background and Objective:Patients with Alzheimer's disease have impaired visual function even in the early stages of the disease. Therefore, the present study aimed to determine the visual signs and symptoms in patients with Alzheimer's disease and compare them with those in the control group. Materials and Methods:This cross-sectional descriptive study was conducted on 19 Alzheimer patients a...
متن کاملUse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملUse of a Two-Channel Moiré Wavefront Sensor for Measuring Topological Charge Sign of the Vortex Beam and Investigation of Its Change Due to an Odd Number of Reflections
One of the solutions of the Helmholtz equation is the vortex beams. In the recent decades, production and applications of these types of beams have found serious attentions. Determination of the vortex beam topological charge and its sign are very important issues. Odd number of reflections of the vortex beam changes its vorticity. In this paper, we have used a q-plate to generate a vortex beam...
متن کامل